2. Remove the knob from the gas tap.
3. Use an appropriately sized
screwdriver to adjust the flow rate
adjustment screw.
For LPG (butane
–
propane), turn the
screw clockwise.
For natural gas, turn the screw counter-
clockwise once.
NOTE: The normal height of a straight
flame in the reduced position is about
1/4 inch.
4. If the flame is higher than the desired
position, turn the screw clockwise. If
it is smaller, turn counter-clockwise.
5. For the last control, bring the burner
both to high-flame and reduced
positions and check whether the
flame is on or off.
Depending on the type of gas tap used
in your appliance, the adjustment screw
position may vary.
Exchange injector for the broiler
1. Open broiler door.
2. Unscrew fastening screw of the
burner.
3. Slightly pull the broiler burner (1) to
lift it free with its link(s) on the rear
side connected.
4. Unscrew injector by turning in
counter-clockwise direction (3).
5. Fit new injector.
1 Broiler burner
2 Injector holder
3 Injector
Exchange injector for the oven
1. Unscrew fastening screws on the
back wall.