NOTES ON VACCINE STORAGE 

[Recommendations are based on a report from CDC, the Centers for Disease Control and Prevention. For 

more information, visit www.cdc.gov/vaccines] 

Vaccines are fragile and they must be maintained at recommended temperatures from the time 
they are manufactured until they are administered. This appliance is designed to keep your 
vaccines at the proper constant temperature while they are stored inside. 

Vaccine Storage Temperatures 

Vaccines are sensitive and lose their potency if exposed to temperatures outside the required 
temperatures (heat or cold).  
 

Live Vaccines

-  These vaccines 

tolerate freezing temperatures 

but deteriorate rapidly 

after removal from the freezer 
 
All varicella-containing vaccines (VAR, Varivax; ZOS, Zostavax; and MMRV, ProQuad)  
should be stored in  a  continuous frozen state, between 

-58 °F  and +5 °F (-50°C and  

-15°C).  
 
Inactivated Vaccines - 

These vaccines are 

damaged by exposure to freezing 

temperatures

. However, they can tolerate short time out of refrigeration.  

 

All inactivated vaccines require refrigerator storage temperatures between 

35°F and 46°F (2°C 

and 8°C)

, with a desired average temperature of 40°F (5°C). The following live attenuated 

vaccines must also be kept at refrigerator temperature: influenza (LAIV, FluMist); rotavirus 
(RV1, Rotarix and RV5, RotaTeq); typhoid (Ty21-A, Vivotif); and yellow fever (YF-Vax). Review 
each manufacturer’s instructions in the product information for vaccine specific storage 
temperatures. Aim for 

40º F

 (

+5 °C

)  to keep temperatures from getting too warm or cold. 

The measles, mumps, rubella vaccine (MMR) can be stored either in the freezer or the 
refrigerator.  
 

Freezing of vaccine is considered to be the main reason for vaccine damage. Freezing is 
where vaccines are  exposed to temperatures at or below 0

o

C.  Although the vaccines 

may not visually appear solid or change in appearance if exposed to these temperatures 
they are considered to be damaged.  As such, visual inspection of vaccines must be 
considered unreliable when assuring vaccine was stored under appropriate conditions. 

 
Live attenuated vaccines and some inactivated vaccines 

must be

 

protected from direct 

sunlight or fluorescent light

. The manufacturer’s product information indicates if the vaccine 

must be protected from light.  

Vaccine Storage Equipment 

Vaccine storage equipment should be selected carefully, used properly, maintained regularly 
(including professional servicing when needed), and monitored consistently to ensure the 
recommended temperatures are maintained. 

Содержание Accucold FF28LWHVAC

Страница 1: ...24LVAC FS30LVAC FS407LBIVAC VT65MLBIVAC INSTRUCTION MANUAL BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS Write Model Serial Numbers here _______________________________...

Страница 2: ...e Thermostat 7 8 Care of the Appliance 8 10 Defrosting 8 Cleaning the Appliance 8 9 Vacation 9 Moving the Appliance 9 Removing Replacing the Base Grille 9 Disposing of a Worn Out Appliance 10 Problems...

Страница 3: ...line away from appliances FOLLOW WARNING CALL OUTS BELOW ONLY WHEN APPLICABLE TO YOUR MODEL Use two or more people to move and install appliance To ensure proper ventilation for your appliance the fro...

Страница 4: ...al company SAVE THESE INSTRUCTIONS TIPS FOR SAVING ENERGY Try not to open the door too often especially when the weather is hot and humid Once you open the door try to close it as soon as possible Whe...

Страница 5: ...our fingers wipe down using warm water then dry In order to prevent damage to the surface of your appliance do not use rubbing alcohol flammable fluids abrasive cleaners or sharp tools when removing t...

Страница 6: ...least 4 of clearance at the top back and sides to allow for proper air circulation 4 Avoid direct sunlight and heat Light can discolor the finish In addition when placed near a heat source such as sto...

Страница 7: ...e grille panel below the door inside the refrigerator or on top of the cabinet If you find it necessary to change the temperature setting for your digital thermostat controlled appliance please refer...

Страница 8: ...level reaches a thickness of 1 4 to 1 2 inch NEVER USE A METAL INSTRUMENT as you can damage the cooling coils which often cannot be repaired this will also void your warranty To defrost disconnect fr...

Страница 9: ...when moving to a new location 1 Remove all contents 2 Unplug the appliance 3 Clean wipe and dry the unit completely 4 Tape down all removable parts so they don t shift and rattle during the move 5 Ta...

Страница 10: ...r dealer remove the appliance or call your local recycling office for the appropriate disposal information For the sake of environmental protection be careful not to damage the rear wall of the applia...

Страница 11: ...ntly opened Warm air entering the appliance causes the motor to run longer Keep the door closed as much as possible Is the thermostat set correctly See Temperature Control on pages 11 12 Is the door c...

Страница 12: ...5 C The following live attenuated vaccines must also be kept at refrigerator temperature influenza LAIV FluMist rotavirus RV1 Rotarix and RV5 RotaTeq typhoid Ty21 A Vivotif and yellow fever YF Vax Rev...

Страница 13: ...nes in the box helps to maintain the vaccine at the appropriate temperature Temperature Monitoring Devices Thermometers with alarm function Thermometers are a critical part of good storage and handlin...

Страница 14: ...cessing the outlet or circuit breaker are likely to see it Storage units should be plugged directly into wall outlets multi strip outlets should not be used If possible do not plug more than one appli...

Страница 15: ...liance is being repaired Regularly check the door seals to ensure a good seal is maintained Replace the seals if they are damaged or cold air is leaking from the appliance Defrost the appliance regula...

Страница 16: ...tes 5 Repairs to parts or systems resulting from unauthorized modifications made to the appliance 6 Expenses for travel and transportation for product service in remote locations 7 The removal and rei...

Отзывы: