background image

Item No. 0AH-00-001  Revised:  07/24/12         

 

EZ-Vent INSTALLATION 

INSTRUCTIONS 

Models: 1600 Series

 

Below are four types of ventilation options available with the 1600 series range hoods. 

7” Round, Vertical Discharge

 

Knock-out both top openings.  Mount the duct work to the 7” 
round discharge recessed into the top of the hood.  Be cautious 
not to block the fan or damper blades with screws.  Remove the 
charcoal filter pad, baffle plate, and 3”x10” damper and discard.  
An optional 7” round damper is available (part number 5AH-35-
707).  

3 1/4” x 10”, Vertical Discharge (from top of hood) 

Knock-out top 3”x10” duct opening near the back.  Attach 3”x10” 
damper plate on the top of the hood with damper blade opening 
to a vertical position. Remove charcoal filter pad and discard.  
For best results, seal all seams with duct tape. 

3 1/4” x 10”, Horizontal Discharge (from rear of hood) 

Knock-out rear 3”x10” duct opening.  Attach 3”x10” damper 
plate on the back of the hood with damper blade opening to 
horizontal position.  Remove charcoal filter pad and discard.  
For best results, seal all seams with duct tape. 

Re-circulating (non-vented / ductless) 

The range hood is shipped in this configuration.  No 
modifications are required. 

Remove Phillips head screw holding in the baffle plate and 
discard both.  
Remove Phillips head screw holding 3”x10” damper plate and 
discard both.  For best results, seal all seams with duct tape. 

** Revision 2/09 – Electrical cut-out is   

now located on the opposite side     
than shown.  While facing the hood 
it is now located on the right-side  
rear.  We no longer provide an  
electrical cut-out on the rear.   