Operating Your Refrigerator 

 

Temperature Control: 

 

Your appliance

’s evaporator system is out of sight behind the interior rear wall.  

 

The interior temperature is controlled with a thermostat knob 
located inside the unit, towards the upper right-hand corner. 
Turn the knob clockwise from the 

STOP

 (

0

) position toward 

the higher numbers for colder temperatures. Higher settings 
on the knob (higher numbers) mean lower temperatures 
(colder) in the refrigerator. 

 

On the coldest settings, temperatures in some spots inside 
the cabinet may drop below 32°F. Use higher thermostat settings only when required 
or recommended. When the ambient temperature is normal, we recommend a 
medium setting. 

 

Changes in the ambient temperature affect the temperature inside the refrigerator so 
choose an appropriate setting of the thermostat knob, depending on ambient 
conditions. 

 

In the 

STOP

 (

0

)

 

position, the appliance does not operate (the cooling system is 

switched off), yet the power supply is not interrupted (the light still works). 

 

The temperature inside the refrigerator also depends on how often you open the 
door. 

 

In all small refrigerators without interior fans, temperatures are coldest near the 
bottom, and occasionally near the rear. Place contents accordingly. It is best not to 
operate these units mostly empty. If temperatures are erratic, try putting some water 
bottles inside to create a load for the compressor. 

NOTES:  

1.  Shelves are adjustable. Certain models include glass shelves (see 

Technical 

Information

, page 5). These shelves stop short an inch before the back wall, which is 

essential for air flow and the proper operation of the automatic defrost system. Do not 
block these gaps.  

2.  a) Interior lighting on the FF6 series models is controlled by a switch that is activated  

    by the opening and closing of the refrigerator door.  
b) Lights on the other models are controlled by a manually-operated rocker switch. To  
    maintain the proper interior temperature, keep the light on only as long as 
    necessary. 

3.  If the refrigerator is unplugged, has lost power, or is turned off, you must wait 3 to 5 

minutes before restarting it. If you attempt to restart before this time delay, the unit will 
not start. 

 

Defrosting Your Appliance: 

This appliance operates with an automatic defrost system, so the refrigerator defrosts 
itself. While the compressor is operating, ice will build along the rear cold wall (the 
evaporator plate is behind the wall). During the compressor’s off-cycle, ice will melt, drip 
down, collect in the trough at the bottom and drain through a small hole into a tray above 
the compressor; 

where the compressor’s heat will evaporate the water. If you notice 

excessive ice build-up on the rear wall, try setting the thermostat to a slightly warmer 
setting; be sure that the door gasket is sealing well and that there is no obstruction of the 
drain hole at the bottom rear of the interior cabinet. 

 

Содержание accucold FF6 Series

Страница 1: ...LD brand FF7 series ACCUCOLD brand FF7COM SUMMIT Commercial FF7BCOM SUMMIT Commercial SCR600L ACCUCOLD brand SCR600BL SUMMIT Commercial 405 CM411L Instruction Manual BEFORE USE PLEASE READ AND FOLLOW...

Страница 2: ...duce the risk of fire electrical shock or injury when using the appliance follow basic precautions including the following Plug into a grounded 3 prong outlet Do not remove grounding prong do not use...

Страница 3: ...en to operate play with or crawl inside the refrigerator Do not use solvent based cleaning agents or abrasives on the interior These cleaners may damage or discolor the interior Do not use this appara...

Страница 4: ...ng Your Appliance Care and Maintenance 10 Cleaning Your Appliance Power Failure Vacation Time Moving your Appliance Energy Saving Tips Troubleshooting 11 Limited Warranty 15 Location of Parts Temperat...

Страница 5: ...BL FF7BCOM Defrost water outlet NOTE Lock on models FF7L and FF7LBL is located on the front of the door near the top center Handle FF7 series FF7COM FF7BCOM Temperature control dial thermostat light s...

Страница 6: ...elves and lock glass door Capacity 5 5 cu ft Electrical Input 115V AC 60Hz Rated Current 1 0A Refrigerant R134a 1 8 oz Installation Free standing Unit Dimensions W x D x H 23 63 x 23 5 x 33 5 NOTES 1...

Страница 7: ...it away from direct sunlight and sources of heat oven heater radiator etc Direct sunlight may affect the acrylic coating and heat sources may increase electrical consumption Extremely cold ambient tem...

Страница 8: ...ersing the Door Swing If you find the direction of opening the door of the appliance inconvenient you can change it Holes on the opposite side have already been prepared at the factory This appliance...

Страница 9: ...ix the lower hinge in the new position 6 Unscrew the handle and place it on the opposite side 7 Some screws are covered with caps Take off these caps before undoing the screws 8 Check the door gasket...

Страница 10: ...water bottles inside to create a load for the compressor NOTES 1 Shelves are adjustable Certain models include glass shelves see Technical Information page 5 These shelves stop short an inch before th...

Страница 11: ...our appliance if you minimize the number of times the door is opened If the power is going to be off for a longer period of time you need to take the proper steps to protect your chilled items Vacatio...

Страница 12: ...air circulation behind the appliance and wipe the dust from the condenser Noise Cooling in refrigeration appliances is enabled by the refrigerating system with a compressor which produces noise How n...

Страница 13: ...12 Notes...

Страница 14: ...13 Notes...

Страница 15: ...14 Notes...

Страница 16: ...t in accordance with electrical or plumbing codes or use of products not approved by warrantor 4 Replacement parts or repair labor costs for units operated outside the United States 5 Repairs to parts...

Отзывы: