Summit Appliance Accucold ACR1151 Скачать руководство пользователя страница 7

 

INSTALLATION INSTRUCTIONS 

 
BEFORE USING YOUR APPLIANCE 

  Remove the exterior and interior packing. 

 

CAUTION:   

After  unpacking  you 

MUST

 allow  this  appliance  to  stand  upright  for  at  least  2 

hours to allow the lubricant and refrigerant to drain back into the compressor and stabilize. 
Failure to do so may adversely affect performance and the lifetime of this unit.  

  Clean the interior surface with lukewarm water using a soft cloth. 

  Install the handle on the door, if it is not already attached. (See page 9.) 

 

INSTALLATION OF YOUR APPLIANCE 

  The appliance is designed for built-in or recessed or free standing installation for indoor use.

 

  Place your appliance on a floor that is strong enough to support it when it is fully loaded. To level  the 

unit, adjust the front leveling legs. 

  For  free  standing  installation,  5

”  (127mm)  of  space  between  the  back  and  sides  of  the  unit,  and  4” 

(102mm) at the top, are suggested. This allows the proper air circulation to cool the compressor and 
condenser. Even for built-

in installation, it is a must to keep ¼” (6.35mm) space on each side and at 

the  top 

and  2” (51mm) at the rear. Take care that  the air  vent at the front of the appliance  is never 

covered or blocked in any way. 

  NOTE: It is recommended that you do not install the appliance near an oven, radiator or other heating 

source.  Direct  sunlight  may  affect  the  acrylic  coating  and  heat  sources  may  increase  electrical 
consumption.  Don’t  install  in  a  location  where  the  temperature  will  fall  below  44°F  (7°C).  For  best 
performance, do not install the appliance behind a cabinet door or block the base grille. 

  Avoid locating the unit in moist areas.  

  Plug the appliance into an exclusive, properly grounded wall outlet.  

 

 

 

 

 

 

ELECTRICAL CONNECTION 

 

 
 
 
 
 

 
This appliance should be properly grounded for your safety.  The power cord of this appliance is equipped 
with a three-prong plug which mates with standard three-prong wall outlets to minimize the possibility of 
electrical shock. 
 
Do not under any circumstances cut or remove the third (ground) prong from the power cord supplied. For 
personal  safety,  this  appliance  must  be  properly  grounded.  Any  questions  concerning  power  and/or 
grounding should be directed toward a certified electrician or an authorized service center. 
 
This appliance requires a standard 115/120 Volt AC  ~60Hz three-prong grounded electrical outlet. Have 
the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded. 
When  a  standard  2-prong  wall  outlet  is  encountered,  it  is  your  responsibility  and  obligation  to  have  it 
replaced with a properly grounded 3-prong wall outlet.  
 
To  prevent  accidental  injury,  the  cord  should  be  secured  behind  the  appliance  and  not  left  exposed  or 
dangling. 
 
The appliance should always be plugged into its own individual electrical outlet which has a voltage rating 
that  matches  the  rating  label  on  the  appliance.  This  provides  the  best  performance  and  also  prevents 

WARNING

 

Improper use of the grounded plug can result in the risk of electrical shock. If the power cord is 
damaged, have it replaced by a qualified electrician or an authorized service center. 

 

 

Содержание Accucold ACR1151

Страница 1: ...151 ACR1403 INSTRUCTION MANUAL BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS Write Model and Serial Nos on lower left corner of inside cabinet here Model No ___________...

Страница 2: ...sion Cord 8 Reversing the Door Swing of Your Appliance 8 Installing the Stainless Steel Handle 9 Operating Your Appliance 9 11 Control Panel 9 10 Sabbath Mode 10 Temperature Memory Function 10 Defrost...

Страница 3: ...let do not remove grounding prong do not use an adapter and do not use an extension cord Replace all panels before operating It is recommended that a separate circuit serving only your appliance be pr...

Страница 4: ...liance should not be located next to ovens grills or other sources of high heat The appliance must be installed with all electrical water and drain connections in accordance with state and local codes...

Страница 5: ...ACR612 Door Shelves 3 Handle Security Lock Ventilation Grille Adjustable Legs Digital Control Panel Cabinet MODEL ACR1151 Door Shelves 6 Handle Security Lock Ventilation Grille Adjustable Legs Cabine...

Страница 6: ...andle Security Lock Ventilation Grille Adjustable Legs Cabinet Digital Control Panel Note This appliance may be used for the storage of medicine and other medical products It features a hospital grade...

Страница 7: ...l fall below 44 F 7 C For best performance do not install the appliance behind a cabinet door or block the base grille Avoid locating the unit in moist areas Plug the appliance into an exclusive prope...

Страница 8: ...of the door opening from either the left or right side The unit is delivered to you with the door opening from the left side Should you desire to reverse the opening direction please follow the rever...

Страница 9: ...ambient temperature is above or below the recommended temperatures the performance of the unit may be affected For example placing your unit in extremely cold or hot conditions may cause interior temp...

Страница 10: ...cooling operations will still take place To initiate Sabbath mode press the POWER and LIGHT keys at the same time for at least 5 seconds The indicator light will flash four times and confirm that the...

Страница 11: ...han 60 seconds the alarm will sound Pressing the Power key once can switch off the audible alarm DOOR LOCK Your unit is provided with a lock and key combination The keys are located inside the plastic...

Страница 12: ...If the appliance will not be used for several months remove all items and turn off the appliance Clean and dry the interior thoroughly To prevent odor and mold growth leave the door open slightly blo...

Страница 13: ...iance turns itself on and off frequently The room temperature is higher than average A large amount of food has been added to the unit The door is opened too often The door is not closed completely Th...

Страница 14: ...the defrost sensor in the evaporator has failed E5 indicates a defrost heater failure E7 indicates a door switch failure Call for service The alarm sounds The appliance door has been open for longer t...

Страница 15: ...15 NOTES...

Страница 16: ...ts not approved by warrantor 4 Replacement parts or repair labor costs for units operated outside the United States 5 Repairs to parts or systems resulting from unauthorized modifications made to the...

Отзывы: