background image

Emergency Pr

ocedure

Soot or Chimney Fire

1. Close damper door by unhooking chain.

2. Close fire door.
3. Do not remove flue pipe before fire is completely out.
4. Call the fire department.

Run-A-W

ay Fire

1. Close damper door by unlocking chain.

2. Close fire door.
3. Close off all air from entering the firebox.
4. Fully open barometric damper to reduce draft.
5. Douse the fire with water to reduce the rate of com-

bustion, if necessary.

Power Failur

e

1. Close damper door by unhooking chain.

2. Close fire door.
3. Remove access door at ??????????????
4. Open all air registers fully and furnace room door to

give better air circulation.

5. Do not load fire box higher than 1/4 way up during

gravity firing.

6. The combustion air can now be supplied by opening

the secondary air control.

7. Open all warm air registers full open. Registers must

not be obstructed by furniture or drapes.

8. Continue to operate a small fire for duration of power

off period. Do not expect to maintain maximum com-
fort under no power conditions. To prevent injury do
not allow anyone who is unfamiliar with the operation
of the furnace attend it.

9. On return to normal power operation, return all altered

items to their normal operating positions.

For more information read labels and manual carefully.

NOTE: THE EXCESSIVE HEAT CAUSED BY AN
EXTREME FIRE MAY DAMAGE THE FURNACE SAFETY
CONTROLS. THEIR OPERATION SHOULD BE CHECKED
BEFORE THE FURNACE IS RETURNED TO SERVICE.

SEE: PROCEDURE FOR CHECKING PROPER FUNC-
TION OF THE LIMIT SAFETY CONTROL.

Содержание SBB

Страница 1: ...IONS BEFORE OPERATING YOUR SUMMERAIRE FURNACE SAVE THESE INSTRUCTIONS FOR REFERENCE THIS FURNACE MUST BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER AND WHERE REQUIRED BY LAW A LICENCED TECHNICIAN SUMMERAIRE MFG PETERBOROUGH ONTARIO FOR SERVICE CALL NAME __________________________ ADDRESS ______________________ __________________________________ TELEPHONE ____________________ ...

Страница 2: ...the combustion air supply A plenum cham ber or an elbow type connection may be used Sufficient air flow must be provided for efficient operation An open ing into the furnace room should be made to the outdoors if there is not sufficient air infiltration The equipment has to be installed in accordance with the standards of the National Board of Fire Fire Underwriters Authorities who have jurisdicti...

Страница 3: ... Fuel Damper Control Drawing 1 The thermostat for the solid fuel section activates the damper control which in turn moves the damper flap It is essential that the damper control is at all time in per fect working order Note Adjust damper chain so that damper flap opens no more than 1 2 When oil is used as fuel close all combustion air inlets to solid fuel side of furnace Excessive air decreases th...

Страница 4: ...nit Blower Unit Fan Limit Bracket Fan Limit Hole location determined by holes provided Note Do not attach BX Conduit to warm air plenum Secondary Air Control Open link in chain Damper motor and bracket Summeraire Model S B B ...

Страница 5: ...out and Installation Fire brick retaining angle fits over top row of bricks Stainless steel brick guard secured inside fire door with two screws Brick layout for floor of fire box chamber Note Install first Summeraire Model S B B ...

Страница 6: ...225B Relay for optional induced draft only Solid fuel relay Junction box Note R8225B Relay not required when damper motor is used Fan and limit must be in this location See drawing detail Blower cabinet may be installed on either side of oil end Summeraire Model S B B ...

Страница 7: ...g No 4 15 5 8 4 14 1 4 Cut out for blower on desired side Corner points of cut out are indicated on both side panels Damper motor and bracket Secondary Air control Secondary Air control Summeraire Model S B B ...

Страница 8: ...vails and the unit is not subject to excessive humidity dust conditions or chemical atmosphere of any type or any kind which may cause accelerated metal corrosion Warranty extends only to the repair or replacement of parts returned freight prepaid to us and which prove defective after inspection and testing by us Any labour involved in effecting repair or replacement is excluded from the warranty ...

Страница 9: ... for good combustion and air circulation Set your thermostat so that it is 7 10 degrees fahrenheit higher than room temperature This will open the draft damper allowing combustion air into the furnace Light the paper and close the fire charging door When the kindling is burning well put in some hardwood and allow this to begin burning Add hardwood do not fill the firebox above the door sill do not...

Страница 10: ...AZARD AND VOID WARRANTY Adjustment of the solid fuel air damper should never exceed 1 2 inch open A fixed limiter is installed on your furnace to insure this maximum opening and is not to be tampered with Do not use chemical or liquids to start fire To charge or inspect solid fuel side with scrap wood push up smoke baffle and secure with smoke baffle tool over door in full open position Do not ope...

Страница 11: ...ir registers b Adjust the oil thermostat to its highest setting in order to keep the burner operating c Insert a duct thermometer to its highest warm air duct at a point 12 inches downstream from the furnace plenum If the limit control is functioning correctly the burner will shut off on high limit before the thermome ter reads 200 F d To begin the test close all the warm air registers then block ...

Страница 12: ...n 1 4 way up during gravity firing 6 The combustion air can now be supplied by opening the secondary air control 7 Open all warm air registers full open Registers must not be obstructed by furniture or drapes 8 Continue to operate a small fire for duration of power off period Do not expect to maintain maximum com fort under no power conditions To prevent injury do not allow anyone who is unfamilia...

Страница 13: ...1 4X 1 2 3 1 4X 1 2 3 1 4X 1 2 PULLEY TURNS 4 1 2 3 1 2 3 1 OPEN MOTOR 1 3 1 3 1 3 1 3 H P BELT 45 46 46 46 SIZE BURNER FAFC 2 FAFC 2 FAFC 3 FAFC 3 SHIPPING 970 970 970 970 WEIGHT Note All nozzles are semi solid spray pattern as specified on label Nozzle shipped in unit is 1 20 80 can be changed within specified ranges for desired output see above WHEN FIRING AT 85G P H U S OR 1 00 G P H U S END C...

Страница 14: ...t flue pipe runs help to keep the gases above the dew point The interior chimney holds and retains heat longer result ing in less condensation than the exterior chimney A good draft produces a hotter fire and exhausts the flue gases outside more rapidly at higher temperatures pre venting condensation of flue products A combination furnace in need of cleaning will have poor draft creating a lazy fi...

Страница 15: ...A Time Delay G L1 N Flame Sensor NOTE IN U S A ALL WIRING TO BE DONE IN ACCORDANCE WITH N F P A 70 NATIONAL ELECTRICAL CODE Oil Relay Damper Motor Oil Wood Thermostats Solid Fuel Relay Ground Burner Motor Field Wired Wire for Two Speed Option Extra Factory Wired Blower Motor L4064L Fan Limit L4064R Fan Limit Summeraire Model S B B ...

Отзывы: