    WARNING

:

•  Use of this thermometer is not intended as a 

  substitute for consultation with your physician.

•  The thermometer is not waterproof! 

  NEVER immerse into liquids.

  CAUTION:

THIS PRODUCT IS NOT A TOY. ADULT SUPERVISION IS

REQUIRED. STORE AWAY FROM CHILD’S REACH.

Thank you for purchasing the One Second Ear Thermometer. Before 
you start using your new Ear Thermometer, please read this operation 
manual thoroughly for the correct methods of usage especially section 
on Safety.
This manual should be kept on hand for easy future reference.

INSTRUCTION MANUAL

ONE SECOND EAR THERMOMETER

Product   

 

One Second Ear Thermometer

Battery Type 

 

 

 

2xAAA 1.5V

Accuracy   

 

 

 

.36°F(0.2°C)

Measuring Range 

 

 

89.6°F-109.22°F(32°C-42.9°C)

Display Resolution   

 

 

 

0.1°

Operating Ambient Temperature Range 

41°F-104°F(5°C-40°C)

Relative Operating Humidity 

 

 

15 to 95%RH

Storage Environment  

 

-13°F-131°F(-25°C to 55°C)

Relative Storage Humidity 

 

 

30 to 95%RH

The ear thermometer meets American Society for Testing and  
Materials accuracy standards (ASTM) with requirements specified in 
ASTM stands E 1965-98 ,as it pertains to infrared thermometers and 
when used under normal operating conditions.

NOTES ON TEMPERATURE

12

03170

Please read the following instructions

 and  warnings carefully. 

Keep this instruction manual 

for future reference. 

Requires 2 AAA batteries (included).

For Technical Support 

Call 1-800-268-6237 

or  E-Mail at

 [email protected] 

For use with children from birth and up. 

We at Summer Infant stand behind all of our products. If you are not 
completely satisfied or have any questions, please contact our
Customer Service Department at 1-800-268-6237 or e-mail us at
 [email protected].

Summer Infant Europe, LTD.

20 Sparrows Herne
Bushey, Hertfordshire
WD23 1FX UK 44 (0)20 8420 4429
Colors and styles may vary.

MADE IN CHINA

 

             7/05

Содержание 3170

Страница 1: ...please read this operation manual thoroughly for the correct methods of usage especially section on Safety This manual should be kept on hand for easy future reference INSTRUCTION MANUAL ONE SECOND EAR THERMOMETER meter A 1 5V 0 2 C 2 9 C 0 1 40 C 5 RH 55 C 5 RH in d 03170 Please read the following instructions and warnings carefully Keep this instruction manual for future reference Requires 2 AAA...

Страница 2: ...r any other purpose Do not use the product on people suffering from ear diseases Do not use the product while the ear canal is wet e g after a swim or a bath This product is not waterproof Therefore keep the product dry at all times Do not operate the device outside the specified ambient temperature range 41 F 104 F 5 C to 40 C and humidity range 15 95 RH Do not store the ear thermometer outside th...

Страница 3: ...erature Normal temperature refers to the body temperature of a healthy person It differs among individuals and is affected by environmen tal conditions such as time of day atmospheric temperature activity before measurement site of measurement e g ear mouth or armpit We recommend that you determine your normal body temperature by measuring several times under the same conditions How Does the Ear T...

Страница 4: ...ated by two AAA batteries for easy replacement Auto off function helps you to save energy in the batteries The ear thermometer is light and compact allowing you to take it everywhere Effectiveness Compared to traditional thermometers which require several minutes to take the temperature the ear thermometer takes only one second to display the measurement It is safer to take the temperature in the ...

Страница 5: ...er exercise or a bath The right ear reading may differ from the left ear Therefore always take the temperature using the same ear External factors may influence ear temperatures including when an individual has been lying on one ear or the other had their ear covered been exposed to very hot or very cold temperatures has just finished swimming or bathing has been wearing hearing aids or ear plugs Sh...

Страница 6: ...d 6 Place the battery in the battery compartment making sure that it is positioned correctly according to the polarities indicated on the thermometer Fig 4 Replace the battery cover by sliding it into place Fig 5 3 Correct Holding Posture Hold the main body as shown in fig 6 so that you can press the button with your index finger PRE USE ...

Страница 7: ...that you take the temperature three times in the same ear If the temperature happens to differ use the highest reading Be aware that slight variations 36 F 54 F 0 2 0 3 C can occur if consecutive measurements are taken Infants 3 months and below Children under 3 years who have a condition such as a compromised immune system and for whom the presence or absence of fever is critical When you are firs...

Страница 8: ...he tip of the probe straight against the ear canal Hold in this position until measurement is completed For measuring your own temperature Hold the main body of the thermometer and insert the probe along your own ear canal Push the probe naturally against the ear canal and insert it further After confirming that the probe and the ear canal are in close contact start the measurement USE OF YOUR PRO...

Страница 9: ...easuring after it beeps about 10 seconds after the last measurement and the ready to measure sign is displayed You can repeat the process again from step 3 onwards 4 Power off Power will be automatically turned if the thermometer is left unattended for 1 minute TROUBLESHOOTING Conditions Possible cause and solution Nothing is displayed after O I button pressed Battery may be worn out Replace with ...

Страница 10: ...ectly Insert the probe correctly Follow inserting the probe into the ear canal under use of your product page 8 If the problem still persists send to service center for repair is displayed There may be a short circuit Please contact service center The ambient temperature has exceeded the specific range of 41 F 104 F 5 C 40 C Measurement will not start after pressing the button Measurement is made w...

Страница 11: ...ghtly moistened with alcohol and immediately dry it with a clean cotton swab After cleaning allow at least 5 minutes to dry before using it again Do not clean the probe with a paper towel or paper as it contains glass fiber which may damage the lens at the tip of the probe After cleaning dry the probe thoroughly before store it To assure a high level of accuracy it is very important to keep the pr...

Страница 12: ... to 55 C Relative Storage Humidity 30 to 95 RH The ear thermometer meets American Society for Testing and Materials accuracy standards ASTM with requirements specified in ASTM stands E 1965 98 as it pertains to infrared thermometers and when used under normal operating conditions NOTES ON TEMPERATURE 12 We at Summer Infant stand behind all of our products If you are not completely satisfied or have ...

Отзывы: