6
B.
Installation instruction
1)
Location and size
The heat pump should be installed in a place with good ventilation
2)
The frame must be fixed by bolts (M10) to concrete foundation or brackets. The
concrete foundation must be solid.
3)
Please don
’
t stack substances that will block air flow near inlet or outlet area, and
there is no barrier within 50cm behind the main machine, or the efficiency of the
heater can be reduced or even stop.
4)
When the machine is running, there will be condensation water discharged from
the bottom. Connect drainage nozzle (accessory) into the hole under the machine
and clip it in, then connect the clear plastic pipe to drain the condensation water
away.
* MINIMUM DISTANCE
Filter
Water processor
Water switch