4.3.14 RS 232 TEST
The RS232 test routine verifies the cutter’s RS-232-C serial communications (transmit
data, receive data, and hardware handshaking) circuits. This test does not require
pen, knife, or media to be loaded.
To run the RS-232-C test, proceed as follows:
1.
Unplug the RS-232-C data cable from the rear panel of the cutter.
2.
Use a loop back test cable to connect pin 2 of the cutter’s data connector to pin 3
and pin 7 to pin 8.
3.
Press
The cutter will start transmitting and receiving data at all available baud
rates and parity settings. The length of the transmissions will vary because of the
different baud rates used. The unit then checks the hardware handshake lines.
Afterwards it will report on the LCD whether it passed the test or not.
4.
Upon completion of the test, remove the loop back test cable from the cutter’s rear
panel RS-232-C connector.
5.
Plug the RS-232-C data cable into the connector.
4.3.15 Align Mode
The OPOS settings are explained in detail in section 3, except for the Alignment
mode.There are three additional alignment methods available on all SummaCut
cutters: X-Alignment, XY-Alignment and XY-Adjustment.
These alignment methods can be used if the combination of marker color – media
color cannot be read by the OPOS sensor.
These alignment methods require that the user manually register markers using the
cutter’s keypad. Most cutting software can automatically put these markers around the
printed graphic.
X-Alignment compensates for errors in media alignment, and therefore graphic
rotation, by rotating the graphic’s contour. This alignment method requires that the
user specify the Origin and one point along the X-Axis. Distance parameters are not
required. X-Alignment is the simplest alignment method.
XY-Alignment compensates for errors in graphic rotation and skew. Skew errors occur
when the graphic’s X and Y Axes are not perpendicular. This alignment method
requires that the Origin and one point along both the X and Y Axes be specified.
XY-Adjustment compensates for errors in graphic rotation, skew, and scale. Scale
errors occur when the graphic’s printed size is different from the graphic’s original size
as created in the imaging software. X-Distance and Y-Distance parameters are
required. These parameters define the distance between the Origin and X-Axis point,
and between the Origin and Y-Axis point. XY-Adjustment is the most accurate manual
alignment method.
Press
, then use
or
to change the alignment method.
Press
to confirm or
to cancel. The default alignment method is OPOS.