S One
User’s Manual
OPOS
3-15
Media calibration ensures that the sensor can recognize the marks. OPOS is calibrated at the
factory to work on a wide range of media. However, certain media -- such as those with a high
gloss -- may not work with the default settings. Before working with such materials, perform a
media calibration t
est. This test will alter OPOS’s sensitivity so that it will read the marks with
greater reliability. Print a square measuring at least 4x4 cm on the used media. Make sure to
use the same ink than the one when creating the registration marks.
NOTE:
If the media calibration is done and results
didn’t improve
, set the media
calibration value again to default.
Perform the media calibration:
1.
Switch the cutter on and load the vinyl with the printed square.
2.
Press Settings.
3.
Scroll down with arrow and
press Calibrations.
4.
Press Calibrate media
(OPOS).
5.
Press Measure.
6.
Use the arrows to manoeuver
the knife in a white area.
7.
Confirm with
.
The cutter will make a circular
movement while it measures
the reflection of the media.
8.
Use the arrows to manoeuvre
the knife in a printed area.
9.
Confirm with
.
S1D160
50000 x 145 mm
Knife
700 mm/s
90 g
Configuration 1
LAN 192.168.10.2
FlexCut
Tool
Actions
Settings
Calibrations
Configuration
Length calibration
Calibrate OPOS
Calibrate media (OPOS)
Calibrations
Set
Measure
Calibrate media (OPOS)
Reset to default
Set tool
above white
area.
X 30.00 Y 50.00
Set tool
above white
area.
X 30.00 Y 50.00
Set tool
above
printed
area.
X .00 Y 50.00
85
Set tool
above
printed
area.
X 30.00 Y 50.00
3.4.2
Media calibration