LYNX2-LC for Optical Cord with Tight Buffered Fiber

Assembly Procedure

ETK1323089B

Flat surface

Lever

Red dot

Lever

PC/UPC

APC

Flange Design

1 direction only

(20) Confirm the position before

heating.

Sleeve at center 

of heater

No gap

Button to 

start heating

(21) Heat Protection Sleeve.

Lynx heater program runs a fan to 

cool the sleeve after heating

(22) Pick up Sleeve.

Be careful for hot sleeve,

spring and flange even after

the cooling by fan.

!

(23) Slide Rear Parts.

Rear Parts

(24) Disassemble Boot / Kevlar

Stopper and Rear Stopper.

(27) Pull out Outer Sheath and 

Kevlar from Rear Stopper.

Sheath

Boot

Rear

Stopper

Kevlar

Stopper

Rotate counter-clockwise.

No twisting

(17) Slide Protection Sleeve until it covers 

the projection of the flange.

No twisting

(19) Set Sleeve into the heater.

If sheath and Kevlar are 

inserted the protection sleeve, 

pull out from the sleeve.

Lightly maintaining 

tension on  fiber

Right side first

Then left side

No twisting

(26) Assemble the housing.

(25) Key Alignment.

(30) Secure Kevlar by Kevlar 

stopper.

(18) Slide the spring onto 

separated sheath.

Kevlar

(28) Slide the Boot and Kevlar

Stopper .

Divide the Kevlar to two bunch.

(29) Push the Kevlar stopper 

lightly.

Rotate clockwise.

(31) Cut the tether.

(32) Complete.

If sheath ride on the 

protection sleeve, please 

cut that amount.

(Do not cut Kevlar) 

!

!