Copyright © 2011 Sumitomo Electric Industries, LTD.
LYNX2-LC for Optical Cord with Tight Buffered Fiber
Assembly Procedure
ETK1323089B
Flat surface
Lever
Red dot
Lever
PC/UPC
APC
Flange Design
1 direction only
(20) Confirm the position before
heating.
Sleeve at center
of heater
No gap
Button to
start heating
(21) Heat Protection Sleeve.
Lynx heater program runs a fan to
cool the sleeve after heating
(22) Pick up Sleeve.
Be careful for hot sleeve,
spring and flange even after
the cooling by fan.
!
(23) Slide Rear Parts.
Rear Parts
(24) Disassemble Boot / Kevlar
Stopper and Rear Stopper.
(27) Pull out Outer Sheath and
Kevlar from Rear Stopper.
Sheath
Boot
Rear
Stopper
Kevlar
Stopper
Rotate counter-clockwise.
No twisting
(17) Slide Protection Sleeve until it covers
the projection of the flange.
No twisting
(19) Set Sleeve into the heater.
If sheath and Kevlar are
inserted the protection sleeve,
pull out from the sleeve.
Lightly maintaining
tension on fiber
Right side first
Then left side
No twisting
(26) Assemble the housing.
(25) Key Alignment.
(30) Secure Kevlar by Kevlar
stopper.
(18) Slide the spring onto
separated sheath.
Kevlar
(28) Slide the Boot and Kevlar
Stopper .
Divide the Kevlar to two bunch.
(29) Push the Kevlar stopper
lightly.
Rotate clockwise.
(31) Cut the tether.
(32) Complete.
If sheath ride on the
protection sleeve, please
cut that amount.
(Do not cut Kevlar)
!
!