7-2
Chapter 7
Troubleshooting
■
Abnormality and its solutions related with this product.
E060 / E069
Option 1 Error 0 / 9
E070 / E079
Option 2 Error 0 / 9
E080 / E089
Option 3 Error 0 / 9
When a communication error occurring between the P1-AG and the inverter, the inverter trips with those
codes.
In case the communication error detected by the P1-AG, "E060, E070, or E080" is shown as the error code.
Additionally, in case the communication error detected by the inverter, "E069, E079, or E089" is shown as
the error code.
Those error codes "E06*, E07*, or E08*" depend on the slot in which the P1-AG is attached.
E068 Option 1 Error 8
E078 Option 2 Error 8
E088 Option 3 Error 8
In case the P1-AG is attached to the unsupported inverter, "E068, E078, or E088" is shown as the error
code.
Those error codes "E06*, E07*, or E08*" depend on the slot in which the P1-AG is attached.
Issue
▶
Possible cause
▶
Possible solution
An error
occurred as
soon as the
inverter
powered on.
・
The P1-AG is
attached to the
unsupported
inverter.
・
Refer to the chapter 5.2 "Supported inverters", attach
the P1-AG to the supported inverter.
Issue
▶
Possible cause
▶
Possible solution
An error
occurred in the
communication
between the
P1-AG and the
inverter.
・
The P1-AG is not
correctly attached.
・
Refer to the chapter 5.3 "Installation", attach the P1-AG
again.
・
There is an
intruding object in
between the P1-AG
and the inverter
connector.
・
Remove the intruding object.