background image

 

 

Technical Information 

KOUTURIGISHI-1078H

 

 

 

Optical Connector Termination Tool 

CAK-0057-EX 

Instruction Manual

 

 

 

 

 

 

 

 

 

2011-03-16     

 

 

SUMITOMO ELECTRIC INDUSTRIES, LTD. 

 

 

 

The information contained herein is presented only as a guide for the applications 

    of our products. No responsibility is assumed by SUMITOMO ELECTRIC for any 

    infringements of patents or other rights of the third parties which may result from 

    its use. No license is granted by implication or otherwise under any patent or patent 
    rights of SUMITOMO ELECTRIC or others 

The information contained here may be changed without prior notice. It is therefore 

    advisable to contact SUMITOMO ELECTRIC before proceeding with the design of   
    equipment incorporating this product.

 

 

     

 

 

© Sumitomo Electric Industries, Ltd. 

Содержание CAK-0057-EX

Страница 1: ...ssumed by SUMITOMO ELECTRIC for any infringements of patents or other rights of the third parties which may result from its use No license is granted by implication or otherwise under any patent or pa...

Страница 2: ...f optical fiber 7 4 2 Batteries exchange 7 5 Assembling procedure for H PCF cables cords 8 5 1 Preparatory work for optical fiber cable 8 5 2 Preparatory work for the optical fiber cord 9 5 3 Preparat...

Страница 3: ...rrule assembly tool JRFK 57 in use It may cause injury Caution Use tools according to this instruction manual Wrong usages may cause injury damage of the tool or sub Attention standard assembled conne...

Страница 4: ......

Страница 5: ...Component parts of CAK 0057 EX 1 Optical fiber cleaver 2 Ferrule assembly tool 3 Microscope CAT 0057B 1 CR CF2071 5 Scissors 1 6 1 7 Instruction manuals English KOUTURIGISHI 1078 1 Carrying case 4 Cap...

Страница 6: ...ollar 4511 2 Collar Quantity 1 2 Figure Code VJA7084 CB CF2071 3 Cord Bush Quantity 1 1 Figure Code VJM7069 SP CF1071 4 Coil Spring Quantity 1 2 Figure Code VJA7218 CP CF2071 5 Plug Cap Quantity 1 1 F...

Страница 7: ...Plug Case Ferrule Collar Coil Spring Plug Cap Cord Bush Plug Case Ferrule Collar Coil Spring Plug Cap Optical Fiber Cord Optical Fiber Cord Cord Bush 1 CF 1071 2 CF 1571 Optical Fiber Cord 6 Collar Pl...

Страница 8: ...can be seen by adjusting focusing dial Attention When the microscope is not in use close its arms to prevent batteries from exhausted Focusing dial Ferrule adaptor 1 open 4 2 Batteries replacement Ope...

Страница 9: ...your own knife Fig 3 Remove length 200mm Reference value Fig 4 2 Cut off the hold tape the filler and the filler cords at the end of the sheath with the scissors to expose the optical fiber cords and...

Страница 10: ...g 8 5 3 Preparatory work for the ferrule attaching process Fig 10 1 Insert the cord into the outer jacket remover of the ferrule assembly tool from its front face label face and then grasp the handle...

Страница 11: ...collar into the cord jacket Note Please make the collar projected from the cord jacket by no more than 1mm Fig 14 4 Keep the strength member folded and strand it tightly Fig 15 5 Put the optical fibe...

Страница 12: ...the protective coating should be less than 5mm Fig 19 7 Adjust the length of the strength member to 5 to 6mm with scissors Fig 20 5 to 6mm Fig 20 Note Make sure to leave the strength member 5 to 6mm...

Страница 13: ...he optical fiber Important 8 Hold the optical fiber cord black 2 2mm dia by a hand and tip the bare optical fiber core cladding 3 to 4 times gently with a finger of another hand so that the fiber bend...

Страница 14: ...Make sure to insert the optical fiber cord into the ferrule exactly until the folded strength member projects no more than 2mm from the bottom of the ferrule Fig 27 Fig 27 The tip of the strength mem...

Страница 15: ...33 Ferrule guide Flange Ferrule Fig 32 Fig 34 handle 6 Grasp the handle till it goes no more touching on the limit screw with pushing the optical fiber cord slightly toward the ferrule in order not t...

Страница 16: ...ard and slowly press up the lever to the end then the optical fiber will be cut properly Don t touch the ferrule when pressing the lever It can cause poor cleave quality Don t press up the lever fast...

Страница 17: ...the optical fiber The faces of the optical fibers together with those of the ferrules will be seen with a microscope compare them with examples shown next page If they correspond to any of sub standar...

Страница 18: ...led to the axis of the fiber Fig 48 Sub standard sample The length of the crack is more than 1 10 of the core diameter Fig 46 Sub standard sample Hackle is observed on the face Crack Fig 47 Hackle 17...

Страница 19: ...springs and the cord bush don t get out of their places See below and Fig51 52 This procedure will be easier when the plug case is held slightly inclined as shown in Fig 51 52 Plug cap should be pushe...

Страница 20: ...ttention White marking arranged symmetrical position Set the ferrules so that the white mark on the optical fiber cord connected to one connector may be symmetrical to that on the optical fiber cord c...

Страница 21: ...is removed the plug cap and the plug case should be replaced with new ones They may be damaged with put in and remove procedure Remove operations should be done with care to prevent human body from g...

Страница 22: ...ferrule doesn t go out of the plug case enough and it cause coupling loss increase Fig 61 3 To examine the connector assembled correctly pull the optical fiber cord lightly 20N on and off holding the...

Страница 23: ...ed 2 Use cable holder or so for the cable not to sway Be careful not to press the cable and fiber cords with the holder 3 Keep minimum radius bend of both cables and optical fiber cords Hold back the...

Страница 24: ...ame Product code Sales unit set Optical Connector Termination Tool Kit CAK 0057 EX Optical Fiber Cleaver FOCUS200 EX Ferrule Assembly Tool JRFK 57 1 Product name Product code Sales unit set CF 1071 CF...

Страница 25: ...assembly tool 5 3 6 4 It is difficult to insert the optical fiber cord into the ferrule The strength member is put aside The protective coating semitransparent is not properly removed from the end of...

Страница 26: ...65 3 Screw up the two hexagon bolts on the blade positioning plate avoiding pushing it sideward Fig 66 Don t push the blade positioning plate sideward It can cause the cleaver trouble 4 Try the opera...

Страница 27: ...p the lever It cause that cloth is hold with chuck Fig 71 Please look that cloth is held with chuck Fig 72 3 With holding cloth chucked pull cloth out of chuck obliquely upward Fig 73 Don t pull cloth...