8. Daily inspection and Maintenance
Table 21 Approximate Amount of Grease Supply for Helical BUDDYBOX [g]
Single Stage Type
Double Stage Type
Size
Mounting Direction
Size
Mounting Direction
Y1,Y2,Y3,Y4
Y5,Y6
All of Direction
Input Side
Input Side
Input Side
Z609
□
Z609DA
A610
□
A610DA
B612
□
B612DA
C614
□
Oil Lubrication
150~225
B612DB
D616
□
250~375
C614DA
8.5~12.5
E617
□
335~500
C614DB
20~30
D616DA
20~30
D616DB
40~60
D616DC
85~125
E617DA
20~30
E617DB
40~60
E617DC
85~125
Note: • Because shaded section
indicates Long-life grease models, they do not need to supply grease.
•
□
indicates either 0 or 5.
• Refer to page 26-28 for approximate amount of oil supply for the part of oil lubrication.
(4) Procedure for Supplying and Draining of Grease
Procedure for supplying grease for
grease-lubricated models
(excl. maintenance-free type)
1 Remove the grease discharge plug from the outside cover.
2 Supply grease with a grease gun from the grease nipple in the inside cover section or motor connection cover.
3 Attach the grease discharge plug.
Fig.27 Position of Grease Drain Plug (Example: EHYM Type)
Grease fitting
Grease drain plug
・
Supply grease during operation to ensure proper, uniform circulation.
・
Supply grease slowly.
・
Do not supply grease more than the amount shown in Table 20 and 21. Grease temperature rise or grease leakage to motor part
because of agitation heat.
Grease Replacement of Grease-Lubricated and Maintenance-Free Models
・
The unit may be used for a long time safely, because long-lifetime grease is sealed in. However, overhaul every 20,000 hours or
3-5 years of operation ensures even longer lifetime.
・
Always consult our specialized factory for overhaul of gearmotors and reducers. Experience is necessary for overhaul.