background image

 

15

7  Related Drive Parameters

7 Related Drive Parameters

No.

Name

Description

Default

b1-01

Frequency 
Reference 
Selection 1

Selects the frequency 
reference input source.
00 : Operator - Digital preset 

speed d1-01 to d1-17.

01 : Terminals - Analog input 

terminal A1.

02 : MEMOBUS/Modbus 

communications

03 : Option Potentiometer

01

H3-13

Analog Input 
Filter Time 
Constant

Sets the primary delay filter 
time constant for terminal A1. 
Used for noise filtering.

0.03 s

Содержание AI-V3/J-H

Страница 1: ...ype AI V3 J H NOTICE 1 Make sure that this installation manual is delivered to the end user of inverter unit 2 Read this manual before installing or operating the inverter unit and store it in a safe...

Страница 2: ...patent liability is assumed with respect to the use of the information contained herein Moreover because Sumitomo is constantly striving to improve its high quality products the information contained...

Страница 3: ...AND SAFETY 4 2 RECEIVING 8 3 PRODUCT OVERVIEW 9 4 OPTION COMPONENTS 10 5 INSTALLATION PROCEDURE 11 6 OPERATING INSTRUCTIONS 14 7 RELATED DRIVE PARAMETERS 15 8 TROUBLESHOOTING 16 9 OPTION SPECIFICATIO...

Страница 4: ...are available for the Potentiometer Option Option Unit Inverter SF 520 Option Potentiometer Technical Manual Read this manual first The Technical Manual is packaged with the Potentiometer Option and...

Страница 5: ...cause drive damage Inverter SF 520 Series Operating and Maintenance Manual No DM2201E To obtain instruction manuals for Sumitomo products access these sites http www cyclo shi co jp SF 520 Series Tech...

Страница 6: ...ust be installed according to this manual and local codes The following conventions are used to indicate safety messages in this manual Failure to heed these messages could result in serious or possib...

Страница 7: ...1 Preface and Safety 7 CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates an equipment damage message...

Страница 8: ...meter Option does not function properly contact your supplier Components packaged with the option The Potentiometer Option AI V3 J H Technical Manual Tool Requirements Use a flat blade screwdriver wit...

Страница 9: ...Overview About Product The Potentiometer Option allows the user to adjust the frequency reference by rotating a potentiometer dial Turning the potentiometer changes the frequency reference making it e...

Страница 10: ...Option Components Dimensions The installed option adds 21 mm 0 83 in to the total depth of the drive A Potentiometer Dial C Drive Connector B Option Model Number D Connection Tabs SF 520 Min Max A B...

Страница 11: ...ait at least one minute after all indicators are off The drive has internal capacitors that remain charged even after the option is disconnected The drive charge LED will extinguish when the DC bus vo...

Страница 12: ...over from the drive 2 Insert the connector on the back of the option into the CN5 port on the drive and click it into place NOTICE Damage to equipment Make necessary parameter adjustments after instal...

Страница 13: ...g the option interface 1 Insert a flat blade screwdriver into the small opening between the drive and the option Gently apply pressure to the connection tabs to disconnect the option as shown Undersid...

Страница 14: ...to the potentiometer Set drive parameter b1 01 03 2 Adjust the frequency reference by turning the potentiometer dial NOTICE Damage to equipment Use caution when setting the frequency reference by adj...

Страница 15: ...Selects the frequency reference input source 00 Operator Digital preset speed d1 01 to d1 17 01 Terminals Analog input terminal A1 02 MEMOBUS Modbus communications 03 Option Potentiometer 01 H3 13 Ana...

Страница 16: ...Option Unit Fault Cause Possible solution The option unit is not properly connected to the drive Turn the power off and reconnect the option unit LED Operator Display Fault Name oPE05 Frequency Refer...

Страница 17: ...ification Model Number AI V3 J H Storage Installation Area Indoors an area free from oil mist and dust Ambient Temperature 10 to 50 C Humidity 95 RH or less with no condensation Storage Temperature 20...

Страница 18: ...ted under the conditions described in the catalog or as otherwise agreed upon in writing between the Seller and Buyer or its customers the Seller will provide at its sole discretion appropriate repair...

Страница 19: ...l provided or designated by the Seller 3 Improper use or operation of the Product by the Buyer or its customers that is not in formed to the Seller including without limitation the Buyer s or its cust...

Страница 20: ...rmal wear and tear or deterioration of the Product s parts such as the cooling fan bearings 9 Any other troubles problems or damage to the Product that are not attributable to the Seller Others The Se...

Страница 21: ...Specifications dimensions and other items are subject to change without prior notice No DM2205E 1 0 Printed 2015 03...

Отзывы: