Symptom 

Solution 

Not or less water come out 

1

st

. Make sure turn on the shut-off valve 

2

st

. Inspect all connector for ensuring no stemming inside      

3

st

. Make sure hot and cold water both has enough water, the pressure balance valve 

will stop water running suppose one of hot/cold water supply system is waterless 
or only supply low water pressure water. 

Leaking from handle 

1

st

. Replace the cartridge 

2

st

.Replace the O-ring. 

Less water come out from showerhead 

1

st

. clean the calcification in showerhead nipple   

LCD screen shutdown 

1

st

. Recharge battery with charger 

2

st

. Replace battery 

3

st

. Replace electronic module 

LCD display error code “E10” 

1

st

. Insert and extract the sensor connector repeatedly 

2

st

. Ensure all connection are solid and not pseudo soldering. 

3

st

. Ensure the sensor wires are not discontinued. 

LCD display error code “E20” 

1

st

. Drying the sensor connector if water resided. 

2

st

. Drying the circuit board if water resided 

LCD display error code “E30” 

1

st

. Hardware or Software Original authorization Invalid, contact SUMERAIN technical 

support center. 

LCD backlight doesn’t activated 

1

st

. the shower water’s temperature is less than predefined threshold value 

Big temperature measurement error   

1

st

. Drying the sensor connector if water resided. 

2

st

. Drying the circuit board if water resided 

3

st

. Temperature sensor invalid.   

LCD screen has steam 

1

st

. Loose and take off the LCD screen, drying the transparent plate and reassemble. 

 
 

 

 
 
 
 
 
 
 
 
 

HONGKONG SUMERAIN SANITARY INDUSTRY CO., LIMITED   

 

Address: ROOM 1018, HOLLYWOOD PLAZA 610 NATHAN ROAD MONGKOK, KL   
Factory Address: 25 building Tangkou Industrial Park,Shuikou town, Kaiping City, Guangdong Province, China (Mainland) 
Tel:   +86-750-2731579 
Toll Free: 400-0999-075 (China mainland) 
Fax:  +86-750-2715258 
Web:    http://www.sumerain.com 
E-mail: 

[email protected]

   

 
SUMERAIN INTERNATIONAL GROUP – AMERICA SALES Branch   
 

Address:    13455 Harper Dr.   
          Saratoga, CA 95070 
          USA 
Tel: +1-408-867-8884   
FAX: +1-408-867-4272 
E-mail: 

[email protected]

   

 
 
 

Содержание S3134CD-B

Страница 1: ...MODEL S3134XD B Version 1 2 Pressure Balanced Shower Waterfall Tub Faucet with Digital Temperature Display MODEL FINISH S3134CD B CHROME S3134ND B BRUSHED NICKEL...

Страница 2: ...questions regarding this product call 86 750 2731579 or email to supports sumerain com Sincerely SUMERAIN customer service department 1 Unpack your new product and ensure that all the parts are conta...

Страница 3: ...WILL NOT PAY FOR A Conditions malfunctions or damage not resulting from defects in material or workmanship B Conditions malfunctions or damage resulting from normal wear and tear improper installation...

Страница 4: ...Material Brass Showerhead Flow rate 6 81L M 1 8 GPM Hand shower Flow rate 4 54L M 1 2 GPM Tub Spout Material Stainless steel Tub Spout Reach 179mm 7 1 16 Inch Tub Spout Width 96mm 3 3 4 Inch Recommend...

Страница 5: ...FRONT VIEW OF SHOWER TUB FAUCET...

Страница 6: ...SIDE VIEW OF SHOWER TUB FAUCET...

Страница 7: ...accordance with all local and state plumbing and building codes 2 SHUT OFF WATER SUPPLY Locate water supply inlets and shut off the water supply valves These are usually found near the water meter if...

Страница 8: ...001 Concealed Box 1 PCS B3100002 Rough in valve 1 PCS B3100003 Sleeve 1 PCS B3100004 Pressure balance cartridge 1 PCS B3100005 Temperature limiting Ring 1 PCS B3100006 Bonnet nut 1 PCS B3100007 Escutc...

Страница 9: ...INSTALLATION 5 1 Make a mounting rack normally use woods as materials for preparing install the concealed box assembly the mounting board s face should be Min 63mm 2 15 32 and Max 85mm 3 11 32 behind...

Страница 10: ...6 VALVE TRIM INSTALLATION 6 1 Turn on your shut off valve for cleaning the hot and cold water supply pipe before connect to the valve body allow the water flush 3 5 minutes to flush out dirt and debri...

Страница 11: ...inlet and then connect to valve inlet with elbow hot left cold right Mixer Valve Connecting thread for Hot Cold water inlet G1 2 1 2 BSPP US CA customers may require NPT cover to BSPP adapter for con...

Страница 12: ...ur hot and cold water supply again if no leaking 6 4 Drill the mounting holes exactly according to mixer valve and elbow position done the finish wall Cut the plaster shield around the finish wall sur...

Страница 13: ...6 5 Remove the valve sleeve by Phillips screwdriver and hold the screw for next step fastening battery box...

Страница 14: ...6 6 Attach the battery to the concealed box and fasten with screw 6 7 Connect the battery s power wire to the circuit board for power supplying...

Страница 15: ...t center supports sumerain com Error code E10 display indicate Sensor open circuit or temperature value less than 1 C 33 8 F Error code E20 display indicate sensor short circuit or temperature value m...

Страница 16: ...6 10 Battery charging inspects Please make sure the charging sign 3 active on LCD screen when connect to AC DC USB recharger which have been plugged LCD SCREEN DEFINED...

Страница 17: ...6 11 Take off the escutcheon and the temperature limit ring 6 12 Turn on and adjusting the cartridge to achieve desired shower water s maximum temperature...

Страница 18: ...6 13 Attach the temperature limit ring to cartridge for locking the maximum temperature Attach the escutcheon to the bonnet too 6 14 Seal the wall around the plaster shield with waterproof sealant...

Страница 19: ...dle onto the valve stem and tighten set screws by the Allen wrench that is provided Please don t over tighten Done the same procedure on diverter knob Finally press in the screw cover 6 16 Valve trim...

Страница 20: ...hower arm escutcheon to the shower arm and apply Teflon tape on the thread of shower arm Secure the shower arm into the pipe elbow inside the wall by rotating clockwise US CA customers may require NPT...

Страница 21: ...7 2 Put the screen washer into the connector of showerhead and secure the showerhead on the shower head arm by hand rotating anticlockwise Missing the screen washer might lead to shower invalid...

Страница 22: ...8 TUB SPOUT INSTALLATION 8 1 Apply Teflon tape on the thread of spout and Screw the thread into the pipe elbow inside the wall US CA customers may require NPT cover to BSPP G1 2 adapter for connecting...

Страница 23: ...ted when the water s temperature more than the predefined threshold value Initial threshold 35 C 95 F the light color will display according to predefined as below The scald caution will appear suppos...

Страница 24: ...rface or the spout you can clean it by a commercial limescale remover such as Lime Away or CLR Dilute the remover according to the label instructions The faucets might have some rusty if your faucet u...

Страница 25: ...water resided 2st Drying the circuit board if water resided LCD display error code E30 1st Hardware or Software Original authorization Invalid contact SUMERAIN technical support center LCD backlight...

Отзывы: