SUMERAIN S2140 W Series Скачать руководство пользователя страница 13

SUMERAIN SANITARY GROUP     WWW.SUMERAIN.COM

 

 

6.2  

Attach the escutcheon over the valve body.

 

 

 

 

 

 

 

 

 

 

 
6.3

    Place handle onto the valve stem and tighten set screws by using the Allen wrench that is provided. (Please don’t over tighten), 

Then attach the screw cover onto handle.

 

 

 

 

 
 

 

 

 

 

 

 

 
6.4

 

 

Install finish

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

7. INSPECTION   

7.1 

Turn on hold and cold water supply and check all connection for ensuring no leaking anywhere.

 

INSTALL FINISH 

 

Содержание S2140 W Series

Страница 1: ...AIN SANITARY GROUP WWW SUMERAIN COM INSTALLATION GUIDE MODEL S2140XW Version 1 0 WALL MOUNTED TUB FILLER FAUCET MODEL FINISH S2140CW Chrome S2140NW Brushed Nickel S2140DW Matte Black S2140BGW Brushed...

Страница 2: ...assisting you in the future If you have any questions regarding this product call 1 866 203 0866 or email to supports sumerain com Sincerely SUMERAIN customer service department 1 Unpack your new pro...

Страница 3: ...ear with respect to SUMERAIN and commercial products THIS WARRANTY DOES NOT COVER AND SUMERAIN WILL NOT PAY FOR A Conditions malfunctions or damage not resulting from defects in material or workmanshi...

Страница 4: ...Two Number of Handles One Handle style Lever Faucet Total Height Adjustable Spout Reach 6 11 16 Spout width 7 7 8 Spout Height Adjustable Installation type Wall mounted Valve Type Ceramic cartridge Va...

Страница 5: ...SUMERAIN SANITARY GROUP WWW SUMERAIN COM DIMENSION FRONT VIEW OF SHOWER SIDE VIEW OF SHOWER FAUCET...

Страница 6: ...e mounting surface thoroughly 3 CHECKING THE CONTENTS OF THE BOX Upon opening the box check to ensure that all the following items are included If any of these items are missing please contact SUMERAI...

Страница 7: ...proper shower function Operating pressure at the control valve Max 1Mpa Recommended operating pressure 3 bar pressure Hot water temperature Max 60 degree centigrade 140 Fahrenheit 5 Rough in Valve In...

Страница 8: ...ter supply pipe before connect to the valve body allow the water flush 3 5 minutes to flush out dirt and debris Shut off the water supply again after finish HOT WATER SUPPLY COLD WATER SUPPLY 5 3 Loca...

Страница 9: ...your valve body type copper tubing iron pipe or Pex 5 5 Install the feed pipe for spout Rough in Valve connecting thread of mixer water outlet NPT 1 2 US CA or G1 2 Other and turn on hot and cold wat...

Страница 10: ...SUMERAIN SANITARY GROUP WWW SUMERAIN COM 5 6 Done the finish wall 5 7 Apply Teflon tape on the thread of adapter and then connect to mixer outlet for tub spout...

Страница 11: ...SUMERAIN SANITARY GROUP WWW SUMERAIN COM 5 8 Attach the spout adapter onto the supply nipple by the Allen wrench 5 9 Secure the spout to spout adapter with set screw by Allen key...

Страница 12: ...ERAIN COM 6 VALVE TRIM INSTALLATION 6 1 Remove the plaster guard cover and check all connection for leaks Please recover the plaster guard cover after leaking test Please shut off your hot and cold wa...

Страница 13: ...dle onto the valve stem and tighten set screws by using the Allen wrench that is provided Please don t over tighten Then attach the screw cover onto handle 6 4 Install finish 7 INSPECTION 7 1 Turn on...

Страница 14: ...e some rusty if your faucet under hard water condition please rub it with aluminum foil dipped in water until the surface is nice and smooth and wipe it use a small amount of chrome polish or maybe so...