ATEX warning statements
(refer to nameplate to check if applicable)
1. Where a grinder is to be installed in a potentially explosive atmosphere ensure that this has
been specified at the time of purchase and that the equipment has been supplied accordingly
and displays an ATEX nameplate or is supplied with a certificate of conformity. If there is any
doubt as to the suitability of the equipment, please contact Sulzer before commencing with
installation and commissioning.
2. Process liquids or fluids must be kept within -20°C
– 40°C, otherwise the surface of grinder or
system components may become an ignition source due to temperature rises.
3. Electrical installation and maintenance work should only be carried out by suitably qualified and
competent persons and must be in accordance with relevant electrical regulations.
4. If there is a risk of an accumulation of explosive gases or dust, proper ventilation must be
performed before and during operation, removing all gases and dust.
5. When fitting drives, couplings, and guards to a grinder unit it is essential that these are correctly
fitted, aligned and adjusted in accordance with the installation instructions. Failure to do so may
result in sparking due to unintended mechanical contact, or temperature rises due to mechanical
or electrical overload.
6.
Failure to operate or maintain the grinder and ancillary equipment in line with the manufacturer’s
instructions may lead to premature and potentially dangerous failure of components. Regular
inspection, and where necessary, replacement of bearings, seals, other wearing parts and
lubrication is essential.
For unit specific ATEX grinder arrangement drawings, please use the following table to ensure you
have the correct unit drawing for reference.
JWC/Sulzer unit drawings & ATEX certification data
Drawing no.
Unit description
ATEX zone
10000-CD-ATEX-S
10K Inline Series Muffin Monster
Gas & Dust
10002-CD-ATEX-S
10K Channel Series Muffin Monster
Gas & Dust
30002-SC2-ATEX-S
3-SHRED Series Muffin Monster
Gas & Dust
30004T-CD-ATEX-S
30K Inline Series Muffin Monster
Gas & Dust
30005-CD-ATEX-S
30K Channel Series Muffin Monster
Gas & Dust
40002-CD-ATEX-S
40K Channel Series Muffin Monster
Gas & Dust
40002-IL-CD-ATEX-S
40K Inline Series Muffin Monster
Gas & Dust
40002-SC2-ATEX-S
4-SHRED-Series Muffin Monster
Gas & Dust
CMD-XDS2.0-ATEX-S
CMD-XDS2.0 Channel Monster Series
Gas Only
CMD-XDM2.0-ATEX-S
CMD-XDM2.0 Channel Monster Series Gas Only
CDD-XDS2.0-ATEX-S
CDD-XDS2.0 Channel Monster Series
Gas Only
CDD-XDM2.0-ATEX-S
CDD-XDM2.0 Channel Monster Series
Gas Only
CDD-XDS2.5-ATEX-S
CDD-XDS2.5 Channel Monster Series
Gas Only
CDD-XDM2.5-ATEX-S
CDD-XDM2.5 Channel Monster Series
Gas Only