7
3.
Technical specifications
Features
Boiler
C18 kW
Boiler
C24 kW
Units
Weight
230
232
Kg
Height
1305
1305
mm
Width
667
667
mm
Depth
744
744
mm
Fume discharge pipe diameter
100
100
mm
Reservoir capacity
60
60
kg
Maximum heating capacity
410
523
m³
Maximum overall thermal power (air/hydro)
18
23
kW
Minimum thermal power (air/hydro)
6,5
6,5
kW
Minimum fuel consumption
1,6
1,6
kg/h
Maximum fuel consumption
4,5
5,8
kg/h
Rated electrical current
134
134
W
Electric power at start-up (<10 min.)
434
434
W
Rated voltage
230
230
V
Rated frequency
50
50
Hz
Thermal yield at rated thermal power
89,6
89,3
%
Thermal yield at reduced thermal power
91,8
91,8
%
Combustion gas flow (max.)
19
21
g/s
Combustion gas flow (min.)
10
11
g/s
Max. gas temperature
148
172
ºC
CO emissions at rated thermal power
0,009
0,014
%
CO emissions at reduced thermal power
0,038
0,038
%
Draught in the chimney
12
12
Pa
Boiler's water volume
22
22
L
Fume extractor noise emission
49,1
49,1
dB(A)
Table 1
– Technical specifications
Содержание 18 kW Compact Boiler
Страница 15: ...12 a b ...
Страница 42: ...39 f g Figure 19 Installing the programmable thermostat ...
Страница 49: ...46 a b Figure 28 a Remove the screws b Remove the exhauster Figure 29 Vacuum the air flow pipes ...
Страница 56: ...53 12 5 Symbols Figure 34 Symbols ...
Страница 57: ...54 13 Electrical diagram of the pellet boiler Figure 35 Electrical diagram ...
Страница 64: ...61 Flow chart 2 Disconnecting the machine ...