11
OPERATION
3.4
NORMAL STOPPING
1.
Position Start-Run valve to
START
. Close all service valves.
2.
Run engine at low idle for 2 minutes.
3.
Open and close the service valve to reduce pressure to approximately 75 psi or less.
4.
Press ignition switch to
OFF
.
3.5
SULLIVAN-PALATEK ELECTRONIC CONTROLLER (SPEC)
OPERATIONAL INSTRUCTIONS
The buttons for operation will be referred to
numerically based upon the image at right.
Button functionality can vary depending on the
operator input required for each page. Pages
requiring custom button functionality will display
button function icons directly above the buttons.
GAUGE (HOME) SCREEN
The Gauge screen shows current engine and
compressor conditions. Additional warnings are
displayed within the RPM gauge.
Button 2 will show any fault codes;
Button 3 is the Main Menu button. It activates the
Main Menu shown below.
MAIN MENU
This screen allows the user to check user settings,
service reminders, setpoints, and the software
version.
Buttons 1 and 2 cycle between the selections;
Button 3 returns back to the Gauge screen;
Button 4 will display any faults;
Button 5 enters into the option selected with
buttons 1 and 2.