37
TROUBLESHOOTING
6.4
DISCHARGE PRESSURE IS TOO HIGH OR RELIEF VALVE BLOWS
POSSIBLE CAUSE
ACTION
Regulator valve faulty or mis-adjusted
Properly adjust the regulator.
Rebuild/replace the regulator if necessary.
Inlet valve not closing properly
Check the white sealing ring for the poppet valve, to
ensure it is intact and not damaged.
Ice or debris in control lines
Clean debris from the control lines.
Thaw out the control lines to remove the ice buildup.
Optional Heater Kit available
–
consult Factory for
information. Direct the lines so there is a low point to
drain any condensate.
Pressure relief valve faulty
Replace the faulty relief valve.
Oil separator plugged
Replace the oil separator.
Inlet valve leaks at base
Replace O-ring.
Compressor shaft seal leaking
Replace the compressor shaft seal and retest.
6.5
RELIEF VALVE BLOWS WITH THROTTLE LEVER IN IDLE POSITION
POSSIBLE CAUSE
ACTION
Inlet valve not closing properly
Check the white sealing ring for the poppet valve, to
ensure it is intact and not damaged. (185–375 CFM
compressors)
Rebuild/replace valve.
6.6
PRESSURE DOES NOT BLOW DOWN AFTER SHUTDOWN
POSSIBLE CAUSE
ACTION
Automatic blowdown valve may be faulty
Check operation of the automatic blowdown valve.
Replace if necessary.
Air line from inlet valve or sump to blowdown valve may
be restricted
Verify the pilot signal is reaching the automatic
blowdown valve.
Verify the blowdown valve is plumbed correctly.
6.7
COMPRESSOR OIL LEVEL IS DECREASING EXCESSIVELY
POSSIBLE CAUSE
ACTION
Oil line leaking
Repair or replace any leaking lines and retest.
Oil cooler leaking
Repair or replace the leaking oil cooler and retest.
Compressor shaft seal leaking
Replace the compressor shaft seal and retest.
Oil in service line
See
section.
6.8
OIL IN SERVICE LINE
POSSIBLE CAUSE
ACTION
Oil return line plugged or restricted
Remove the oil return line and clean.
Separator element plugged or damaged
Replace the separator element and change compressor
oil.
Discharge pressure below 90 psi
The air demand may be too much. Add compressors or
decrease the demand.
Adjust the discharge pressure above 90 psi.
Check MPV operation; rebuild/replace as needed.
Condensation in sump tank
Drain condensation from sump tank.
Содержание D185PKR
Страница 6: ...vi WARRANTY ...
Страница 8: ...viii About This Manual ...
Страница 24: ...16 Operation ...
Страница 32: ...24 Component Description ...
Страница 42: ...34 Maintenance ...
Страница 48: ...40 Troubleshooting ...
Страница 49: ...NOTES ...