SRL Service Manual
Revision 00
July 2007
Page 50 of 56
10.3.2 How to Change the Service Required (Sr) Warning Interval:
1) Press
the
Alarm Reset
&
Alarm Report
buttons
simultaneously
to access the User Parameter
Menu. The display will show you are at Parameter “A1”.
2) Press
the
Down
button repeatedly to scroll down to Parameter “B9”
.
3) Press
Enter
to access this parameter. The display will show you it’s value is “6” (6000 hours).
(The value cannot be changed by pressing the Up or Down buttons.)
4) Press
the
Up
&
Enter
buttons
simultaneously
for
5 seconds
. This unlocks the parameter
so it can be modified)
.
5) Press
the
Up
or
Down
buttons to change it’s value (min = 1000 hours, max = 999,000 hours)
6)
Press
Enter
to save your changes and exit the parameter.
The display will show you are at Parameter “B8”.
Press
Exit
to exit the User Parameter Menu. The display will show the dewpoint if the dryer is on,
“OFF” if the dryer is off, or “rOF” if the dryer is in Remote Off Mode.
&
&
or