![Sullair SR-1000 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/sullair/sr-1000/sr-1000_user-manual_1390401008.webp)
7
Code: 02250145
--
604 SR
--
250 --- SR
--
3000
English
---
Third screen:
the TENS are shown and the
green dryer on LED
flashes simultaneously.
In this way the composition of the working hours is obtained.
To exit the display of the working hours
press
the reset/report key again.
SETTING THE OPERATING PARAMETERS
To set the operating parameters proceed as follows: with the unit switched off (main
switch in position 0).
1)
Turn
the main witch from position 0 to position I,
holding down
the on off button.
2) The initials “CC” will be displayed.
3)
Press
the on off button; the words on the display will alternate between “CF” and
the unit of measure set for the temperature.
Press
the reset key to change the unit
of measure (
˚
C,
˚
F).
4)
Press
the on off key to access the “tA” parameter adjustment (the display will
alternate between the initials “tA” and its set value);
press
the reset/report key to
set the desired temperature [preset value 43
˚
F (6
˚
C)]. Every time the tA key is
pressed the temperature will increase by +1
˚
C / 1
˚
F.
5)
Press
the on off key to pass on to the “tb” parameter adjustment (the display will
alternate between the initials “tb” and its set value);
press
the reset key to set the
maximum temperature desired [preset value 50
˚
F (10
˚
C)].
6)
Press
the onoff toaccessthe “tC” parameteradjustment (the display willalternate
between the initials “tC” and its set value). Adjustment is made as described in
the point above;
press
the reset buttonto select the desiredvalue (onor oF)[preset
value oF].
7)
Press
the on off key to select the high dew point temperature warning threshold
(the display will alternate between the initials “Ht” and its set value);
press
the
resetbuttontoadjustthewarningthreshold[presetvalue59
˚
F(15
˚
C)].Foradjust-
ment see point 4).
8)
Press
the on off key. The display will alternate between the initials “Id” and its
set value);
press
the on off key.
9)
Press
the on off key to select the alarm relay operation mode (see point c) para.
4.2);
press
the reset key to change the parameter value [preset value on = relay
active without alarms].
10)
Press
the on off key to exit the settings and store all the configured parameters.
11)At this point the dryer can be started up
pressing
on off.
N.B.:
If the tC register has been set on “on” then the “CM” function will be enabled.
SETTING THE DATE OF THE LAST MAINTENANCE OPERATION
1)
Turn
the main switch from position 0 to position I
holding down
the reset button.
2) The “CL” code
will be
displayed.
3)
Press
the on off key to access the last maintenance operation date setting. The
display will alternate between the initials “AA”, which stands for “Year”, and the
year of the last maintenance operation set.
Press
the reset key to forward the
value displayed.
4)
Pressing
the key
the display will alternate between the initials “MM”, which
stands for “Month”, and the month set.
Press
the reset key to forward the value
displayed.
5)
Pressing
the key
vthe display will alternate between the initials “GG”, which
stands for “Day”, and the day set.
Press
the reset key to forward the value
displayed.
6)
Pressing
the on off key the values set are recorded.
4.4 Alarms and Warnings
HP --- High pressure alarm
When the high pressure switch triggers the fridge compressor is stopped. The display
will alternate between the alarm code initials
HP
and
PI
. Once the cause is removed
(before proceeding make the unit safe as reported in para. 3.3),
press
the reset key
to eliminate the alarm.
Содержание SR-1000
Страница 13: ...12 Code 02250145 604 SR 250 SR 3000 English 12 ...
Страница 25: ...24 Code 02250145 604 SR 250 SR 3000 Français ...
Страница 37: ...36 CÓDIGO 02250145 604 SR 250 SR 3000 Español ...
Страница 49: ...48 CÓDIGO 02250145 604 SR 250 SR 3000 Português ...
Страница 61: ...60 Code 02250145 604 SR 250 SR 3000 Deutsch ...
Страница 65: ...64 Code 02250145 604 SR 250 SR 3000 Fig 3 Positioning of labels attached to the dryer SR 250 SR 500 s m p ...
Страница 107: ...106 Code 02250145 604 SR 250 SR 3000 ...