background image

S

HOP

T

EK

 CONTROLLER USER INTERFACE MANUAL

SECTION 4

24

02250180-094 R00

4.4

DISPLAY SCREEN

Information relevant to the compressor operation is
presented in three views on the controller display
screen: Normal View, Main Status Views, Customer
Set Views.

In addition to the standard views, two information
screens are displayed when power is first supplied to
the compressor.  Refer to 

Figure 4-1

.  The first

screen shows “SULLAIR” along with the serial
number of the compressor.  Refer to 

Figure 4-2

.  The

second screen shows the total operation time of the
compressor along with the controller software
revision level and date of manufacture.  Each of
these screens will display for 3 seconds before the
Normal View is displayed.

Figure 4-1: Information Screen 1

Figure 4-2: Information Screen 2

NORMAL VIEW

The Normal View is the default view for the display
screen. When in Normal View, information regarding
the compressor current operating conditions appears
on the display screen. See 

Figure 4-3

.

The top line of the display screen in Normal View
shows the current compressor operating mode and
state.  The lower line of the Display Screen displays
the discharge pressure and the internal temperature
of the compressor package.

Figure 4-3: Display Screen Normal View Example

The Display Screen will also display fault conditions
when they occur.

MAIN STATUS VIEW

The Main Status View shows real-time machine
measurement information.

This information is quickly accessed using the Down
navigational arrow. The top line of the display screen
will indicate the measurement  . See 

Figure 4-4

. The

second line will show the current value of the
measurement being viewed.

Figure 4-4: Display Screen Main Status View 

Example

Listed below are compressor attributes that may be
viewed in the Main Status View.

TOTAL RUN TIME

 – Displays the total time the

compressor has been running loaded or unloaded.

LOADED TIME

 – Displays the total time the

compressor has been running loaded.

MAIN (A)  

- Feature not available.

THIS RUN TIME

 – Displays the total time the

compressor has been running loaded or unloaded
since the most recent startup.

THIS LOADING

 – Displays the total time the

compressor has been running loaded since the most
recent startup.

OIL FILTER

 – Displays the total time on the oil filter

since the last service.

A-O SEPARATOR 

- Displays the total time on the

separator element since the last service.

AIR FILTER 

– Displays the total time on the air filter

         SULLAIR
 XXXXXXXXX

    RUN: XXXXXXH
 REV: X.X     2007/01

AUTO             LOAD
 

174°F             62PSI

TOTAL RUN TIME:
 

337H     20M

Содержание ShopTek

Страница 1: ...warranty WARRANTY NOTICE PART NUMBER KEEP FOR FUTURE REFERENCE USER MANUAL SULLAIR CORPORATION The information in this manual is current as of its publication date and applies to controller part numbe...

Страница 2: ...cated at Michigan City Indiana Instruction includes training on the function and installation of Sullair service parts troubleshooting common faults and malfunctions and actual equipment operation The...

Страница 3: ...TRAPMENT SECTION 2 STARTUP PROCEDURES 13 2 1 INTRODUCTION 13 2 2 CONTROLLER PANEL LAYOUT 14 2 3 START UP PROCEDURES 15 2 4 SHUTDOWN PROCEDURE SECTION 3 ADJUSTMENTS 17 3 1 INTRODUCTION 17 3 2 COMPRESSO...

Страница 4: ...RMAL VIEW SERVICE REMINDERS 27 4 8 NORMAL VIEW WARNING MESSAGE 27 4 9 FAULT MESSAGES SECTION 5 TROUBLESHOOTING 29 5 1 TROUBLESHOOTING INTRODUCTION 29 5 2 TROUBLESHOOTING GUIDE 30 5 3 MACHINE BEHAVIOR...

Страница 5: ...rein are applicable to most compressors and the concepts behind these statements are generally applicable to all compressors 1 2 PERSONAL PROTECTIVE EQUIPMENT A Prior to installing or operating the co...

Страница 6: ...including air line anti icer system antifreeze compound or fluid film to accumulate on under or around acoustical mate rial or on any external surfaces of the air com pressor Wipe down using an aqueo...

Страница 7: ...codes or regula tions B DO NOT use air line anti icer systems in air lines supplying respirators or other breathing air utili zation equipment and DO NOT discharge air from these systems into unventi...

Страница 8: ...andling any ungrounded conductors 1 9 LIFTING A If the compressor is provided with a lifting bail then lift by the bail provided If no bail is provided then lift by sling Compressors to be air lifted...

Страница 9: ...a cles at floor level and transport and corner at minimum practical speeds N Make sure pallet mounted compressors are firmly bolted or otherwise secured to the pallet prior to attempting to forklift o...

Страница 10: ...NOTES 10...

Страница 11: ...d to stop the compressor operation Up Arrow Pad Used to navigate up the list of display messages and to increase or change parameter values for adjustments Down Arrow Pad Used to navigate down the lis...

Страница 12: ...ressor 3 Disconnect and lockout power according to lockout tagout procedure 4 Exchange any two of the three fan motor leads at the fan motor starter Refer to the compressor User s Manual 5 Recheck the...

Страница 13: ...mode is desired use the arrow pads to navigate to the Load Mode parameter Press the pad to change the mode Navigate to the desired mode Automatic or Manual Press the pad to accept and save the mode s...

Страница 14: ...NOTES 16 02250180 094 R00...

Страница 15: ...Section 3 3 3 2 COMPRESSOR ADJUSTMENT PROCEDURES The following steps are to be used to modify a control parameter 1 Use UP arrow and DOWN arrow pad on the controller to navigate to select CUSTOMER SE...

Страница 16: ...he stop button RESTART TIME Set time sec that must pass after the machine is stopped before it can be restarted ON OFF MODE Used to specify LOCAL or REMOTE starting When REMOTE mode is set user must p...

Страница 17: ...ler display language POWER FREQ Select incoming power frequency PHASE PROT Select incoming power phase protection to be INACTIVE DRAIN OPEN Set time sec for drain to remain energized Machines are not...

Страница 18: ...H XXXXH XXXXH XXXXH XXXXH XXXXH XXXXH XXXXH XXXXH XXXXH DRAIN REMOTE REMOTE STAR DELTA TIME LOAD DELAY TIME UNLOAD RUN TIME STOP DELAY TIME RESTART TIME ON OFF MODE LOCAL AUTO LOAD MODE CLEAR OIL FILT...

Страница 19: ...compressor will stop after running unloaded for the period set in the UNLOAD RUN TIME setting When operating in a group of sequenced compressors this removes only this compressor for service If the co...

Страница 20: ...NOTES 22 02250180 094 R00...

Страница 21: ...values for adjustments Return Reset Pad Angled arrow key pad used to return to upper menu when changing parameters A long hold is used to clear fault messages Right Arrow Pad Used to make selection i...

Страница 22: ...ure and the internal temperature of the compressor package Figure 4 3 Display Screen Normal View Example The Display Screen will also display fault conditions when they occur MAIN STATUS VIEW The Main...

Страница 23: ...n s Normal View See Figure 4 6 Figure 4 6 Compressor Operating Mode Display The compressor operating modes are described below Automatic mode Indicated by the word AUTO appearing in the upper line of...

Страница 24: ...played as compressor initiates startup processes A timer is also displayed which counts down the start time This time is set with STAR DELTA TIME in the CUSTOMER SET menu RUN MODE Displayed after the...

Страница 25: ...ons to be taken Figure 4 9 Controller Display Normal View Warning Message 4 9 FAULT MESSAGES When a Fault condition occurs the machine will shut down and the display will indicate STOP on the upper li...

Страница 26: ...NOTES 28 02250180 094 R00...

Страница 27: ...ck for loose wiring b Check for damaged piping c Check for parts damaged by heat or an elec trical short circuit usually apparent by discol oration or a burnt odor Should your problem persist after ma...

Страница 28: ...e button Check wiring Replace button if necessary HIGH PRESSURE Faulty pressure sensor Check and replace pressure sensor if defective High pressure Check operation of valves and controls Faulty unload...

Страница 29: ...NOTES 69...

Страница 30: ...sors LTD Princes Highway Hallam Victoria 3803 Australia Telephone 61 3 9703 8000 Fax 61 3 9703 8053 www championcompressors com au SULLAIR CORPORATION 3700 East Michigan Boulevard Michigan City Indian...

Отзывы: