6: Maintenance
ST18 & ST22 (U.S.A. & Mexico) Operation & Maintenance Manual
88291013-137 R05
34
Subject to EAR, ECCN EAR99 and related export control restrictions.
9. Reassemble and reinstall the spring cham-
ber.
10. Turn the adjusting screw clockwise until it is
under pressure from the spring.
11. Readjust the pressure regulator using inlet
modulation procedures.
6.4.11 Drive coupling maintenance
1. Shut down the compressor.
2. Mount the motor end sleeve on the motor
spindle.
3. Mount the air end sleeve on the air end shaft
so that the air end disc end contact the
shoulder of air end shaft.
4. Slide the elastomer into the discs.
• The gap between the end surfaces of the
two discs should be 2 to 3 mm.
5. Tighten the set screw on the discs.
6.5
Main motor operation and
maintenance
• Ambient temperature
≤
40°C (104°F)
• Altitude
≤
1000 m (3280 ft)
Figure 6-6: Pressure regulator
1. Adjusting screw
7. Valve plate nut
2. Locking nut
8. Locking washer
3. Spring chamber
9. Valve plate
4. Gasket
10. Membrane
5. Spring seat
11. Bolt
6. Spring
12. Retainer ring
13. Valve body
Pressure regulator repair kit part number: 250019-453
WARNING
Isolate the compressor from the power supply
before making any repairs or adjustments to the
drive coupling.
Figure 6-7: Flexible drive coupling
1. Motor end sleeve
2. Elastomer
3. Air end sleeve