S
HOP
T
EK
™
USER MANUAL
SECTION 6
58
02250180-090 R00
6.3
MAINTENANCE EVERY 2000
HOURS
After 2000 hours of operation:
1. Clean the return line strainer. Refer to
and
.
2. Replace the fluid filter. Refer to
and
.
3. Pull fluid sample for analysis.
4. Replace air filter. Refer to
and
and
5. Check belt tension. Re-tension or replace as
necessary. Refer to
.
6.4
FLUID MAINTENANCE
Drain the separator tube and change the compressor
fluid using instructions shown in the Lubrication
Guide.
6.5
FILTER MAINTENANCE
Refer to
. Replace the fluid filter under any
of the following conditions, or whichever occurs first:
1. Every 2000 hours a display on the Controller
indicates the need for replacement
2. Every fluid change.
F
LUID
F
ILTER
R
EPLACEMENT
Refer to
1. Use a strap wrench to remove the filter and
gasket.
2. Dispose of filter properly.
3. Clean gasket seating surface.
4. Apply a light film of fluid to the filter gasket.
5. Hand tighten until gasket is seated.
6. Continue tightening filter an additional 1/2 to
3/4 turn.
7. Replace any lost fluid. Do not overfill.
8. Restart compressor and check for leaks.
Figure 6-2: Return Line Strainer
ST1100, ST1500, 15-20HP
1. Strainer
2. Separator Tube
NOTE
Dispose of fluids in accordance with
applicable federal, state and local
regulations.
Figure 6-3: Fluid Filter Assembly
1. Fluid Filter
Содержание ShopTek ST1100
Страница 10: ...NOTES 8...
Страница 22: ...NOTES 20 02250180 090 R00...
Страница 39: ...NOTES 37 02250180 090 R00...
Страница 48: ...S HOP T EK USER MANUAL SECTION 3 46 02250180 090 R00 Figure 3 14 Wiring Diagram SRS 25 100 115 230V 1 60...
Страница 49: ...SECTION 3 S HOP T EK USER MANUAL 47 02250180 090 R00 Figure 3 15 Wiring Diagram SRS 9 18 220 240V 1 50...
Страница 50: ...S HOP T EK USER MANUAL SECTION 3 48 02250180 090 R00 Figure 3 16 Wiring Diagram SRS 24 30 220 240V 1 50...
Страница 58: ...NOTES 56 02250180 090 R00...
Страница 71: ...NOTES 69...