8.1 - POOR DEWPOINT (cont)
Page 29 of 34
VISUAL
INDICATION
Exessive dust
carryover
Moisture indicator
other than blue
POSSIBLE CAUSE
Desiccant fails to
regenerate
Moisture at indicator
CHECK
Contaminated
desiccant,
Faulty cycle.
Air flow over
moisture indicator
Insufficient purge
air.
Entrained water
Inlet pressure
Inlet Temperature
Air flow demand to
high
Contaminated
desiccant
Faulty cycle
operation.
REMEDY
Ascertain reason for
contamination.
Change desiccant.
Check dryer operation.
Adjust where necessary
Check air flow at moisture
indicator.
Change indicator paper
Chech for correct purge rate,
reset if necessary.
Check pre-fliters/drains.
Check inlet pressure
Check inlet Temperature
Check for peak demand,
exessive air flow
Check for oil carry over etc,
replace desiccant
Check dryer operation,
Adjust where necessary.
Repair or replace