Section 7
MAINTENANCE
39
7.7 TROUBLESHOOTING GUIDE (CONTINUED)
SYMPTOM
PROBABLE CAUSE
REMEDY
P1 HI MESSAGE (continued)
Pressure Regulator Maladjusted
Check operation of pressure regulator.
Solenoid Valve Failed
Check operation of solenoid valve.
to Operate
Control Air Signal Leaks
Check tubework feeding control
signal for leaks.
Control Air Signal Filter Clogged
Service filter assembly.
SEP MNTN MESSAGE
Plugged Separator
Replace separator elements.
dP1 > 10 PSI (0.7 Bar)
Check P1 and P2 pressure transducers.
COMPRESSOR DOES NOT
Air Demand Exceeds Supply
Check air service lines for open
BUILD FULL DISCHARGE
valves or leaks.
PRESSURE
Inlet Air Filter Clogged
Check for maintenance message
on Supervisor display. Clean or
change element.
Inlet Valve Not Fully Open
Check actuation and butterfly disc
position.
Pressure Sensor and/or Connections
Check connections from trans--
at Fault
ducer. If adequate, replace trans--
ducer.
Blowdown Valve Leaking
Replace valve.
LINE PRESSURE RISES ABOVE
Pressure Sensor P2 at Fault
Check connections from trans--
UNLOAD SETTING
ducer. If adequate, replace
transducer.
Unloading Device (i.e., Blowdown
Check operation of unloading device
Valve, Sullicon Actuator, Optional
See Section 7.5.
Spiral Valve) Failed to Operate
Pressure Regulator Maladjusted
Check operation of pressure
regulator.
Solenoid Valve Failed
Check operation of solenoid
to Operate
valve -- See Section 7.5.
Control Air Signal Leaks
Check tubework feeding control
signal for leaks.
Control Air Signal Filter Clogged
Service filter assembly -- See
Section 7.5.
EXCESSIVE FLUID CONSUMPTION
Clogged Return Line Strainer or
Clean strainer -- screen and o--ring
Orifice
replacement kit available. Clean
orifice.
Damaged or Improperly Gasketed
Inspect separator elements and
Separator Elements
gaskets. Replace if damaged.
Fluid System Leaks
Check tube/pipework for leaks.
Fluid Level Too High
Drain excess fluid.
Excessive Fluid Foaming
Drain and change fluid.
NOTE ON TRANSDUCERS:
Whenever a sensor is suspected of fault, the recom-
mended cause of action is to measure the signal
(pressure, temperature, etc.) with an alternate cali-
brated instrument and compare readings. If conflict-
ing, the electrical and/or tubing connections should
be inspected, and if no faults are evident, then re-
place the sensor and re--evaluate against the cali-
brated instrument.
7.8 CALIBRATION
The Supervisor II has software calibration of the
pressure and temperature probes. This calibration
affects the offset but not the slope of the pressure
and temperature calculations. Because of this, the
most accurate method is to heat or pressurize the
transducer to its operating value. If this is too difficult,
room temperature/open atmosphere calibration is
adequate. Calibration may only be done while ma-
chine is stopped and unarmed.
To enter calibration mode, you must press the follow-
ing keys in sequence while in the default status dis-
play mode: “
”
,
“
Y
”
, DSP,
“
B
”
, PRG
Once in
calibration mode, you will see a screen like the follow-
ing:
Содержание LS-20S
Страница 6: ...NOTES...
Страница 23: ...Section 3 SPECIFICATIONS 17 Figure 3 1A Identification Air cooled Model Prior to June 1 2000...
Страница 24: ...Section 3 SPECIFICATIONS 18 Figure 3 1B Identification Air cooled Model After June 1 2000...
Страница 25: ...Section 3 SPECIFICATIONS 19 Figure 3 1C Identification Water cooled Model...
Страница 26: ...20 NOTES...
Страница 31: ...25 NOTES...
Страница 56: ...Section 8 PARTS LIST 50 8 7 COOLER ASSEMBLY AIR COOLED 1 2 3 4 5 5 6 7 8 9 10 11 12 13 14 15 13 14...
Страница 64: ...Section 8 PARTS LIST 58 8 10 AFTERCOOLER PIPING AIR COOLED AFTER JUNE 2000 1 2 3 4 5 6 10 7 8 9 8 10...
Страница 76: ...Section 8 PARTS LIST 70 8 16 ELECTRICAL BOX 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16...
Страница 84: ...Section 8 PARTS LIST 78 8 20 DECAL GROUP 1 2 3 4 5 6 7 8 9 10 11 12 13 14...
Страница 86: ...Section 8 PARTS LIST 80 8 20 DECAL GROUP 15 16 17 18 19 20 21 22 23 24...
Страница 88: ...Section 8 PARTS LIST 82 8 20 DECAL GROUP 25 26 27 28 29...
Страница 90: ...Section 8 PARTS LIST 84 8 20 DECAL GROUP 30 31 32...
Страница 92: ...Section 8 PARTS LIST 86 8 21 DECAL LOCATIONS 1 2 3 4 5 6 7 8 9 10 12 11 15 16 17 18 12 13 14...
Страница 94: ...Section 8 PARTS LIST 88 8 21 DECAL LOCATIONS 9 1 2 3 4 5 6 7 8 10 11 WATER COOLED MODEL 12 13...
Страница 96: ...Section 8 PARTS LIST 90 8 21 DECAL LOCATIONS 1 2 3 5 6 7 4...
Страница 98: ...Section 8 PARTS LIST 92 8 22 WIRING DIAGRAM STANDARD FULL VOLTAGE SUPERVISOR II DELUXE...
Страница 99: ...Section 8 PARTS LIST 93 8 23 WIRING DIAGRAM STANDARD WYE DELTA SUPERVISOR II DELUXE...
Страница 100: ...Section 8 PARTS LIST 94 8 24 WIRING DIAGRAM STANDARD WYE DELTA SUPERVISOR II DELUXE EUROPE...
Страница 101: ...NOTES...