Section 2
DESCRIPTION
12
S
The
sump pressure gauge
continually monitors
the sump pressure at the various load and/or unload
conditions.
S
The
discharge temperature gauge
monitors the
temperature of the air leaving the compressor unit.
The normal reading for the compressor is 230ºF
(110ºC).
Figure 2-7 Air Inlet System (Typical)
Figure 2-8 Instrument Panel
S
The
START pushbutton
turns the compressor
on.
S
The
STOP pushbutton
turns the compressor off.
S
The
RESET (optional) pushbutton
clears the
protective shutdown interlocks after a fault has been
corrected.
S
The
hourmeter
records the cumulative hours of
operation for the compressor and is useful for plan-
ning and logging service operations.
S
The
separator maintenance indicator
monitors
the condition of the separator elements and shows
red when the element restriction is excessive.
S
The
bearing lube filter maintenance indicator
monitors the condition of the bearing filter element
and shows red when the element should be
changed. This indicator is automatically reset.