Device technical spectifications

General

Nominal voltage and frequency

220-240V~AC 50/60Hz

Protection category

Clase I

Ingress protection

IP20

Work temperature

-5 

40ºC

Maximun ceiling slope on which it can be installed

  15º

Weight

5,9Kg

Power consumption in standby mode (W)

<0,5

Service value measurement standard

EN 62879:2020

LED

Wattage

24W

Flux

2400lm

Color temperature

3000,4000,6000K

RGB

No

Data measurement

360º

Nº of ON/OFF cycles

10000

Nº of hours of lifespan

30000h

Dimmable

Yes

Angle

120º

CRI

>80

This product have a light source of energy efficiency class 

F

Fan

Speed

5

Power (W)

34

RPM

220

Airflow (m³/min)

170

Airflow (m³/h)

10200

Max noise level (dB)

35

Service value SV ((m³ / min) / W)

5

Maximum air speed (m / sec)

2,13m/s

purpose. Contact local authorities or your provider 

for recycling advice. Thank you for recycling at 

the collection points provided for this manual.

Note: 

The important warnings and instructions 

indicated in this manual are not guaranteed 

to cover all possible conditions and situations 

that may occur. It must be understood that common sense, 

precaution, and care are factors that cannot be included in all 

products. These factors can and must only be provided by the 

user who maintains and enjoys this fan.

Remote control

Instructions for synchronizing the 

receiver and the remote control

The control is already factory-linked with its receive. 

Make sure all connections are correctly made.

Make sure that the remote control contains batteries.

Make sure that all switches (main and isolation) are on.

The control of this fan have two mode of synchronization, 

Universal mode and Unit mode:

- Unit Mode:

This type of synchronization allows you to control two or 

more nearby fans independently, each with its remote con-

trol.

Synchronization:

The control of this fan does not require synchronization 

with the receiver, the control is already factory-linked with 

its receiver

- Universal Mode:

This type of synchronization allows you to control one or 

more nearby fans with the same remote control.

Synchronization:

1.-Connect the power (wall switch) of the fan or fans that 

you want to control, and then just within the following

15 seconds, press the key   of the remote control for 10 

continuous seconds.

2.-A “beep” sound indicates that the connection has been 

executed and the equipment can function normally.

3.-Now, transmitter and receiver of the fan / s will have 

been synchronized. Turn off the fan / s current using the

switch or automatic and then turn it back on / s, this step 

is the one that closes the synchronization process.

It is not possible for a controller to forget a fan once it has 

been linked, if you want a fan to leave

to obey a command, another one must be linked to 

“overwrite it”.

Preparing for installation

Note: 

The estimated installation time is 120 minutes. This 

product can only be installed by a certified electrician Ca-

refully separate the fan’s parts, avoiding the use of cutters 

or blades that could scratch any part of it.

Remove the fan from the packaging carefully, avoiding the 

use of knives which could scratch any part of it.
Remove all the components. Place the motor on a cloth or 

wet surface so as not to damage its surface finish. Carefully 

handle the unit to make sure that its casing does not bend 

or get scratched.
The fan must be mounted on the floor or a large enough 

table to prevent any component from falling off.

Timer

Nature wind

Turn off fan

Turn off light

Speeds

Change 

color 

temperature

Change 

light

intensity

Summer /

Winter

2h

30’

Содержание 2171531

Страница 1: ...deos instrucciones y una guía de preguntas frecuentes In the event of any questions incidents or missing parts before consulting with your retailer call our customer service department at 916749481 email info sulion es or with technical department at 916749483 email sat sulion es Before calling note of the reference name IMP located on the product sticker or next to the barcode on the box and desc...

Страница 2: ...3 2 ESPAÑOL ESPAÑOL Calle Verano 51 Polígono Industrial Las Monjas 28850 Torrejón de Ardoz Madrid ESPAÑA www sulion es CIF A28763647 34 916774540 ATC 916749481 info sulion es SAT 916749483 sat sulion es ...

Страница 3: ... tras asegurarse de que la alimentación eléctrica general de la instalación está desconectada pormediodeldesmontajedelcorrespondiente fusible o el desarmado del interruptor protector de la instalación para garantizar total aislamiento del suministro eléctrico Español 05 English 11 Instalación del ventilador Fan installation 16 Índice Indice Index1 Componentes Parts Repuestos Spares Herramientas re...

Страница 4: ... del instalador no duden en contactarnos Este aparato pueden utilizarlo niños con edad de 8 años y superior y personas con capacidades físicas sensoriales o mentales reducidas o falta de experiencia o conocimiento si se les ha dado la supervisión o formación apropiadas respecto al uso del aparato de una manera segura y comprenden los peligros que implican Los niños no deben jugar con el aparato La...

Страница 5: ...uidadosamente el conjunto para evitar que su carcasa se doble o arañe El ventilador debe de montarse en el suelo o en una mesa lo suficientemente grande para que no se pueda caer ningún componente Equilibrado Problemas de Balanceo en el funcionamiento del ventilador El balanceo del cuerpo del ventilador durante su funcio namiento no es un síntoma de mal funcionamiento aun llegando al par de centím...

Страница 6: ... por ellos Así mismo si la reparación no es satisfactoria y el objeto no reviste las condiciones óptimas para cumplir el uso al que está destinado el titular de la garantía tendrá derecho a la sustitución del objeto adquiri do por otro de idénticas características o la devolución del precio pagado Términos y condiciones de garantía www sulion es Congratulations on your purchase Congratulations on ...

Страница 7: ... this fan have two mode of synchronization Universal mode and Unit mode Unit Mode This type of synchronization allows you to control two or more nearby fans independently each with its remote con trol Synchronization The control of this fan does not require synchronization with the receiver the control is already factory linked with its receiver Universal Mode This type of synchronization allows y...

Страница 8: ...e fan with slightly loose components screws not adequately tightened or the deformation of blades due to excessively vigorous cleaning may cause exces sive noise and wobbling which will not be covered by the warranty Taking regular care to retighten elements and clean carefully is enough to prevent these problems Control The device s warranty will be invalid if it is installed for use with a solid...

Страница 9: ...28763647 34 916774540 ATC 916749481 info sulion es SAT 916749483 sat sulion es Instalación ventilador Fan installation 2 3 1 OFF 1 2 70 NO INCLUIDOS NOT INCLUDED Green Yellow B la c k Brown Blue G re e n Y e ll o w W h it e Click 1 2 12 13 15 10 11 09 14 3 1 2 1 2 3 4 5 1 2 1 2 3 1 2 3 4 03 05 07 02 01 04 06 08 ...

Страница 10: ...cturedinaccordancewiththefollowingEuropean standards DECLARACIÓN DE CONFORMIDAD CE DECLARATION OF CONFORMITY Madrid 05 11 2021 C Schuller CEO RED 2014 53 EU Article 3 1a EN 60598 1 2015 A1 2018 EN 60598 2 1 1989 EN 60335 1 2012 A11 2014 A13 2017 EN 60335 2 80 2003 A1 2004 A2 2009 EN 62233 2008 EN 62471 2008 EN 62493 2010 Article 3 1b EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 1997 A1 2001 A2 2008 ...

Страница 11: ...www sulion es ...

Отзывы: