20/24
)
EFP-LC TypeE Supplementary manual
(For RX66T)
7.14
Wait command
Command which stops temporarily while script is operating.
Format:
W=xx
* xx : Specifies the number of seconds to pause (Valid until 0-99. Waiting for key input is 0. )
Description example:
W=7 ;The script execution is stopped during the 7 seconds.
W=0 ;The script execution is stopped until START button input
Detail:
The wait command can stop the script operation for 1 to 99 seconds or until the re is a key input.
When the wait command is executed, MCU reset of the target substrate is released.
MCU can operate with the cable for writing connected.
The warning sound ((*pipipi*)) is generated once while stopping the key input waiting at each passage of five minutes.
In case of key entry waiting, after START button is pressed and it is unlocked, commands after Wait command can be
continuously executed. This command can be used any number of times in one PBT file.
Use example:
It is possible to operate the software for simple debugging or demonstration without disconnecting the cable, for
example, when performing write protection after the operation check.
Note:
* In the RX66T series, to reset and cancel boot ID authentication, it may be necessary to set boot ID authentication after
a wait command.
* The normal on-board writer does not release the reset of the target MCU (the target board does not operate) for safety
after the writing is completed. If reset is released after writing, MCU operation may be affected in the circuit to which
the writing cable is connected. When performing an operation check, etc., turn off the power, remove the writing cable,
etc., and then turn on the power to the target board.
* This command may cause a safety problem depending on the circuit configuration of the target board. Please consider
this point carefully and use it at your own risk.
* We cannot take responsibility for any damage caused by use. Also, MCU operation at reset release is not guaranteed.