SUGATSUNE MonoFlat LIN-X hinge Скачать руководство пользователя страница 2

Overall (unit : mm)

• Picture shows the left hand door use.  (Right hand door use is symmetrical.)

Side Board

Door

Overlay Distance

Overlay Distance

• Side overlay as shown in 

Fig.1

 is:

 

19mm for mounting plate 230-P4W-32T: 0mm (Standard)

 

14mm for mounting plate 230-P4W-32T: 5mm

• An opening clearance of 2mm is required on both sides of the door.

Fig.1

max.2

Opening clearance

(Travel legnth : 584)

(340)

(78)

(311)

(70)

15~24

Door thickness

(42.5)

0.6

0.6

Φ35

Φ40

(144.6)

(17.3)

19

Overlay distance

Door edge to side board edge distance

Travel length thickness

230 Hinges mounting plate

thickness : 0mm (Standard)

490

58

295

Door width 550~650

Door height 600~900

40

12

Door edge to bore distance :  5

(245)

(245)

22.5

Pitch between boring and boring

Bore to door : Φ35

                     : Depth min.11

(Connecting plate : 546)

33

50

(245)

(245)

490

12
37

23

Pitch between boring and boring

Installation Position for Door

Installation of Mounting Plate for Cabinet Side Board 

2

LIN-X600

Содержание MonoFlat LIN-X hinge

Страница 1: ...fittings Choose suitable screws to ensure proper installation of the cabinet and door Ensure that door size weight and material correspond to the specifications in this manual Do not disassemble or modify the system WARNING Door Width 550 650 mm 600 900 mm 15 24 mm Max 9 kg per door Door Height Door Thickness Door Weight Product Specification LIN X Body 2 pcs Mounting Plate 2 pcs Connecting Plate ...

Страница 2: ...ce Travel legnth 584 340 78 311 70 15 24 Door thickness 42 5 0 6 0 6 Φ35 Φ40 144 6 17 3 19 Overlay distance Door edge to side board edge distance Travel length thickness 230 Hinges mounting plate thickness 0mm Standard 490 58 295 Door width 550 650 Door height 600 900 40 12 Door edge to bore distance 5 245 245 22 5 Pitch between boring and boring Bore to door Φ35 Depth min 11 Connecting plate 546 ...

Страница 3: ...he two are pointing toward the edge of the door Ensure that the two LIN X bodies are parallel by measuring both the base and mounting plate distances Base Plate Side Mounting Plate Side 4 Connecting Plate Installation 5 Door Installation Tighten Connecting Plate Connecting Nut Connecting Plate Cover Insert Connecting Plate Hinge Installation Pitch Connecting Rod Installation Pitch Ensure that the ...

Страница 4: ...tment Screw Depth Loosen screw adjust the door and retighten screw Vertical and retighten screw Adjustment Screw Loosen screw adjust the door Leveling Adjustment Screw Front Leveling Adjustment Screw Back Loosen both screws adjust the door and retighten screws LIN X600 ...

Страница 5: ...dth 550 650 mm 600 2400 mm 15 24 mm Max 24 kg per door Door Height Door Thickness Door Weight Product Specification Hinge Distance A of Hinges Length of Connecting Bar mm 540 840 1140 1440 1740 2040 2 pcs 490 790 3 pcs 245 395 545 695 845 4 pcs 363 3 463 3 563 3 663 3 5 pcs 347 5 422 5 497 5 35 Depth Door Width 550 650 Door Height 600 2400 Door Thickness 15 24 Bore Distance 295 58 22 5 40 12 12 37...

Отзывы: