5
263
2
×
ϕ
5 additional hole
(For trigger mount)
2
×
ϕ
5 additional hole
(For trigger mount)
ϕ
5.5 additional hole
(For track fixing)
A-492
*
30
18
18
273
FW (Opening width)
About dimension A (See the drawing on page 3 for the detail.)
Single sliding
A = DW (Door width)
=
FW (Opening width) + DN (Margin) + 40
2
Double sliding
A = DW (Door width) + DN (Margin)
=
FW (Opening width) + 40
+ DN (Margin)
2
Cutting and hole processing of standard length parts
1
INSTALLATION PROCEDURE
・
Cut carefully so the cut edge is square to avoid bias and skewing.
・
Make sure to remove any burr. Also check the upper track for any left-over
burr or scrap and remove these.
Caution
This procedure explains installation of single sliding door system.
1-1
Processing of Upper track
⑨
Length = FW (Opening width)
Refer to the figure on the right for cutting and
drilling holes.
DW (Door width) - 50
M6 threading Min. depth 20 mm
2 holes at each end.
1-2
Processing of Horizontal frame
⑦
Length = DW(Door width) - 50 (Thickness of Vertical frame x 2)
M4 threading Min. depth 20 mm
1 hole at each end.
DW (Door width) - 50
Length = DW(Door width) - 50 (Thickness of Vertical frame x 2)
1-3
Cutting and hole processing of Intermediate support
⑬
, when used