Display blank

*Check On/Off switch is illuminated.
*Check external 250mA fuse has not fused.
*Check electric supply: 210-230V 50Hz
*If problem persists contact TECHNICAL SERVICE.

Hydrolysis does not reach maximum intensity

*Check sodium bromide or common salt concentration in water.
*Check cell status (may be incrusted or calcified).
*Clean electrode following instructions in section 6.
*Clean flow detector situated in the cell casing.
*Check titanium cell is not worn (remember that the cell is guaranteed for 5000-6000 
hours (approx. 2-3 years of Summer usage)- see troubleshooting for more information).

Polarity 1 reaches max. intensity but polarity 2 (Auto clean) does not

*IF SALT LEVEL IS CORRECT (1kg./m3)  cell is reaching end of life. As of this moment check intensity every 15-30 days
*When polarity 2 does not reach 50% we recommend substituting cell for a new one if during the summer or maximum usage period. If this should happen in winter change before 
the next season (summer).

Free chlorine levels don't reach 0,2ppm. First thing in the morning

*INCREASE FILTRATION time.
*INCREASE hydrolysis level.
*Check levels of sodium bromide or common salt in the pool (1gr.NaCl/L).
*Check level of isocyanuric acid in pool (30-50ppm.) ONLY if using COMMON SALT.
*Check reactive agents in test kit are not TOO OLD.
*Has the temperature or amount of users risen (see 3.1/3.2 see chapter “Water maintenance”).
*pH is above 7,8 and must be adjusted.

Hydrolysis display shows LO

*Water lacks conductivity (see section 3 “water preparation”).
*Check for incrustations on cell.
*See troubleshooting “Hydrolysis does not reach maximum intensity”.

White flakes in pool

*This happens in excessively hard unbalanced waters.
*Balance the water and check the cell.  clean it if necessary.

Hydrolysis display shows FL

*Check flow detector cable.
*Clean incrustations of flow detector at top of cell casing.
*Check system is free of air (Probe must be always submerged).

RUST on metallic components in pool

*Metallic  elements  lack  standardized  earth  connection.  Contact  an  electrician  to 
solve.
*Rusted components are not stainless steel:
minimum 304- recommended 316.

EARTHING

All metallic components in the pool, such as lamps, ladders, heat exchangers, drains or similar elements within 3.00m. from pool (10feet) must be connected to an earth below 
37Ohms.
WE RECOMMEND HEAT EXCHANGERS BE MADE OF TITANIUM.

CLEANING FILTER

Ensure 

is NOT RUNNING during backwash.

UVSCENIC 

VERY IMPORTANT

REMEMBER that the system needs some time to adapt to your pool and you will have to increase chemical levels for the first 5 days.

WARNING

Keep chemical levels in pool as instructed in this manual

SECURITY

To avoid accidents this product should not be handled by children unless supervised by an adult.
Children should be supervised at all times when in or near a spa, pool or Jacuzzi.

HANDLING AND DOSING DANGEROUS CHEMICALS

Chemicals should be handled with extreme precaution. When preparing ACID, ALWAYS ADD THE ACID TO WATER, never add water to acid!!! VERY dangerous gasses may be 
produced.

EXCESS OXIDATION in water

*Lower Hydrolysis level.
*If your system includes AUTOMATIC REDOX CONTROL check REDOX 
SETPOINT.
*Check REDOX probe and calibrate if necessary.

Titanium cell incrusted in less than 1 month

*Very hard waters with a high pH and total alkalinity (Balance water adjusting 
pH and total alkalinity).
*Check to ensure the system automatically changes polarity (LED's alternate 
every 300min. approx.).
*CONSULT  with  our  technical  service  to  consider ACCELERATING  THE 
polarity change (Auto-cleaning) WARNING: accelerating the polarity change 
decreases the cell life proportionally.

Under normal conditions, the UV lamps placed inside the UV will last 1 year or 8,000 hours. The upper right UVscenic display (display 1) indicates the total hours of operation of the 
UV unit.
If you change de lamps, use new O-rings. When reassembling the unit, make sure the female threads of the compression fittings and male threads of the main structure are 
clean.Then replace and firmly hand tighten the compression fittings. Replace the lamp or fit a new one. Relocate the lampholders and blue lampholder shrouds ensuring that you 
match the correct numbered lampholders.

NOTE: Pinch the blue coating of lamp holder,   when reassembling the unit, to release trapped air. If not released any trapped air may provoce disconnection of lamp holder. 
Reconnect and turn the water supply on, to ensure there are no leaks before you reconnect the power supply.

Routine Maintenance

Содержание UVSCENIC UV 16

Страница 1: ... connection Flow gas detector 1 2 3 4 Cell housing 5 5 4 1 2 3 1 6A fuse Connection U V 14 15 4 3 1 2 10 7 8 9 6 2 3 4 5 11 10 14 15 Optional extras With the HYDROLYSIS system we produce active agents like OXYGEN PEROXIDE HYDROXYLS OZONE on the bases of Water H2O with a minimum conductivity of 1000mS While the Water passes through the hydrolysis cell these oxidative agents are produced This disinf...

Страница 2: ...hen water circulation has stopped TITANIUM CELLconnection overheating Ensure all electrical connections are firmly fixed to avoid false contacts and subsequent overheating of system components Especially concerning the Hydrolysis cell with usage above 33A 10A 10A 16A 16A 25A 25A A B C 1 4 5 13 12 11 10 9 8 min 1m 15 Chlorine pump Optional for models with redox or free chlorine control auxiliary ch...

Страница 3: ...or every m3 of pool water IN POOLS WHICH RECEIVE LARGE AMOUNTS OF STRONG SUNLIGHT 30gr m3 OF STABILYSER Isocyanuric acid MUSTBEADDED This will not be necessary for covered pools SYSTEMS WITH REDOX CONTROL 5 The Redox level advises us of the potential oxidization or reduction level and is used to determine the level of water sterilization The parameters or Set Points are the minimum maximum accepte...

Страница 4: ... Visual inspection to determine scale Monthly checks CLEANING THE TITANIUM CELL Maintenance of the disinfection system hydrolysis consists of cleaning the cell or electrode every 2 3 months should it appear necessary carry out a visual inspection To clean the electrode Remove the cell from its support after turning off the filtration system and closing off the necessary valves Place the electrode ...

Страница 5: ...LEVEL MAXIMUM POWER 100 DISPLAY 2 DISPLAY 3 DISPLAY 4 DISPLAY 5 RECOMMENDED VALUE SEE CHAPTER 5 RECOMMENDED LEVEL 1 500 2 500 OPERATING SYSTEM UV 8 IMPORTANT SAFETYINFORMATION Never look directly into a lamp while UV light is shut on Do not operate dry Do not cover the unit Always disconnect the unit from the power supply and shut the water supply off before performing maintenance The unit may not...

Страница 6: ...ic components in the pool such as lamps ladders heat exchangers drains or similar elements within 3 00m from pool 10feet must be connected to an earth below 37Ohms WE RECOMMEND HEATEXCHANGERS BE MADE OFTITANIUM CLEANING FILTER Ensure is NOTRUNNING during backwash UVSCENIC VERYIMPORTANT REMEMBER that the system needs some time to adapt to your pool and you will have to increase chemical levels for ...

Отзывы: