TROUBLESHOOTING
9
Display blank
*Check On/Off switch is illuminated.
*Check external 250mA fuse has not fused.
*Check electric supply: 210-230V 50Hz
*If problem persists contact TECHNICAL SERVICE.
Hydrolysis does not reach maximum intensity
*Check sodium bromide or common salt concentration in water.
*Check cell status (may be incrusted or calcified).
*Clean electrode following instructions in section 6.
*Clean flow detector situated in the cell casing.
*Check titanium cell is not worn (remember that the cell is guaranteed for 5000-6000
hours (approx. 2-3 years of Summer usage)- see troubleshooting for more information).
Polarity 1 reaches max. intensity but polarity 2 (Auto clean) does not
*IF SALT LEVEL IS CORRECT (1kg./m3) cell is reaching end of life. As of this moment check intensity every 15-30 days
*When polarity 2 does not reach 50% we recommend substituting cell for a new one if during the summer or maximum usage period. If this should happen in winter change before
the next season (summer).
Free chlorine levels don't reach 0,2ppm. First thing in the morning
*INCREASE FILTRATION time.
*INCREASE hydrolysis level.
*Check levels of sodium bromide or common salt in the pool (1gr.NaCl/L).
*Check level of isocyanuric acid in pool (30-50ppm.) ONLY if using COMMON SALT.
*Check reactive agents in test kit are not TOO OLD.
*Has the temperature or amount of users risen (see 3.1/3.2 see chapter “Water maintenance”).
*pH is above 7,8 and must be adjusted.
Hydrolysis display shows LO
*Water lacks conductivity (see section 3 “water preparation”).
*Check for incrustations on cell.
*See troubleshooting “Hydrolysis does not reach maximum intensity”.
White flakes in pool
*This happens in excessively hard unbalanced waters.
*Balance the water and check the cell. clean it if necessary.
Hydrolysis display shows FL
*Check flow detector cable.
*Clean incrustations of flow detector at top of cell casing.
*Check system is free of air (Probe must be always submerged).
RUST on metallic components in pool
*Metallic elements lack standardized earth connection. Contact an electrician to
solve.
*Rusted components are not stainless steel:
minimum 304- recommended 316.
EARTHING
All metallic components in the pool, such as lamps, ladders, heat exchangers, drains or similar elements within 3.00m. from pool (10feet) must be connected to an earth below
37Ohms.
WE RECOMMEND HEAT EXCHANGERS BE MADE OF TITANIUM.
CLEANING FILTER
Ensure
is NOT RUNNING during backwash.
UVSCENIC
VERY IMPORTANT
REMEMBER that the system needs some time to adapt to your pool and you will have to increase chemical levels for the first 5 days.
WARNING
Keep chemical levels in pool as instructed in this manual
SECURITY
To avoid accidents this product should not be handled by children unless supervised by an adult.
Children should be supervised at all times when in or near a spa, pool or Jacuzzi.
HANDLING AND DOSING DANGEROUS CHEMICALS
Chemicals should be handled with extreme precaution. When preparing ACID, ALWAYS ADD THE ACID TO WATER, never add water to acid!!! VERY dangerous gasses may be
produced.
EXCESS OXIDATION in water
*Lower Hydrolysis level.
*If your system includes AUTOMATIC REDOX CONTROL check REDOX
SETPOINT.
*Check REDOX probe and calibrate if necessary.
Titanium cell incrusted in less than 1 month
*Very hard waters with a high pH and total alkalinity (Balance water adjusting
pH and total alkalinity).
*Check to ensure the system automatically changes polarity (LED's alternate
every 300min. approx.).
*CONSULT with our technical service to consider ACCELERATING THE
polarity change (Auto-cleaning) WARNING: accelerating the polarity change
decreases the cell life proportionally.
Under normal conditions, the UV lamps placed inside the UV will last 1 year or 8,000 hours. The upper right UVscenic display (display 1) indicates the total hours of operation of the
UV unit.
If you change de lamps, use new O-rings. When reassembling the unit, make sure the female threads of the compression fittings and male threads of the main structure are
clean.Then replace and firmly hand tighten the compression fittings. Replace the lamp or fit a new one. Relocate the lampholders and blue lampholder shrouds ensuring that you
match the correct numbered lampholders.
NOTE: Pinch the blue coating of lamp holder, when reassembling the unit, to release trapped air. If not released any trapped air may provoce disconnection of lamp holder.
Reconnect and turn the water supply on, to ensure there are no leaks before you reconnect the power supply.
Routine Maintenance