Rev.06
– 03/02/2021
Pag. 28/33
Code: 71207
28.6. MAINTENANCE MASTER PLAN
The adoption of appropriate care and PREVENTIVE maintenance practice for the appliance is a key aspect to assure
the performance and safety in use for any device during its entire lifetime.
For this reason SUEX S.r.l. has designed a layered care and maintenance program for its products, to be put in place
by the Customer organization within the framework agreed by contract in term of roles considered by the
PREVENTIVE maintenance master plan.
Level NAME
Who?
What?
When?
Tools?
Reference
Document?
LEVEL 0
USER
Pre-operation check
list Post - operation
check- list
Every use
No tools
User
Manual
(Usage
sections)
LEVEL 1
MAINTENENER
Preventive
maintenance
(Annual) "Ordinary"
Every 1 year or
100
hes
operating
time
(trhe erlier of the
two occurring)
Equipped
WORKSHOP
Workshop
Manual
– TAG
S2
LEVEL 2
MAINTENENER
Preventive
maintenance
(Quadrennial)
"Extraordinary"
Every 4 years or
400
hrs
operating
time
(the erlier of the
two occurring)
Equipped
WORKSHOP
Workshop
Manual
– TAG
S3
*Those performing maintenance must be properly trained within the SUEX training program, have the relevant
certifications and be equipped with the SUEX tool kit and original spare parts.
No CORRECTIVE maintenance is allowed to the maintenance technician other than the operations and replacement
of the spare parts listed in the workshop manuals in the sections marked with TAG S2 and TAG S3: in any other
case the SUEX TECHNICAL SERVICE must be contacted.
28.7. CONTACT TECHNICAL ASSISTANCE
The technical assistance of Suex s.r.l. is available to answer any of your request:
SUEX s.r.l. - Submarine Exploration
Via Roma, 261/35
31020 VILLORBA
– TV – ITALY
Phone: +39 0422-444849
www.suex.it
For anything not provided for in this manual, reference is made for affinity with the provisions of the Italian civil code
ehile for any dispotes it will be competent the Forum of Treviso.
The prop lock propeller provides a type of propeller that is larger than the standard one:
the white knob protrudes more.
This means that when the SCOOTER, positioned vertically, is placed on the conveyor,
it is necessary to be more careful: any blows to the propeller (which is more protruding)
could damage both the prop lock propeller and the SCOOTER itself.
NOTE: If spray lubricants are used, thoroughly ventilate the inside of the casing, so that
propellant gases do not stagnate: they are almost always flammable!