DETECTOR DE MOVIMIENTO EMPOTRABLE

 

 

INSTRUCCIONES DE EMPLEO 

 

FIG.1 y FIG.2

  

1. 

LED 

2. 

Sensor 

3. 

Regulación tiempo 

4. 

Regulación luminosidad 

5. 

Marco serie 27 de SIMON   

 

DESCRIPCIÓN: 

El detector de movimiento ViaTec está especialmente diseñado para sustituir a un 

interruptor convencional en instalaciones de interior. 

El ViaTec capta las emisiones invisibles infrarrojas procedentes de personas y otras 

fuentes de calor sin emitir ningún tipo de radiación. 

Cuando una fuente de calor se mueve delante del ViaTec su circuito de salida se 

activa. Una vez que deja de captar el movimiento se desactiva tras un tiempo de 

retardo regulable. 

El ViaTec reacciona únicamente  cuando las condiciones de luz están por debajo del 

nivel seleccionado. 

 

INSTALACIÓN Y MONTAJE 

ATENCIÓN: La instalación y el montaje de los aparatos eléctricos debe ser 

realizada por un instalador autorizado.  

ANTES DE PROCEDER A LA CONEXIÓN DEBE ASEGURARSE QUE LOS 

CABLES A CONECTAR NO ESTÁN BAJO TENSIÓN.

 

El aparato está internamente protegido contra las interferencias por un circuito de 

seguridad. No obstante, algunos campos electromagnéticos especialmente fuertes 

pueden llegar a alterar su funcionamiento, por tanto, no debe instalarse próximo a 

campos  inductivos (motores, transformadores, centros de transformación, 

maquinaria industrial, etc.) o señales inalámbricas de alta frecuencia (WIFI, 

telefonía, inhibidores de señal. etc.) 

 

Empotrable, en caja de  mecanismo, evitando que en su área de detección se 

encuentren superficies altamente reflectantes (líquidos, mármol, etc.), elementos 

sujetos a cambios bruscos de temperatura (calefacción, aire acondicionado) o 

fuentes luminosas. 

El  ViaTec  está especialmente diseñado  para ser instalado  en una caja de 

mecanismos con marcos de la Serie 27 de SIMON (

FIG.2

). 

 

Área de detección < 7 m (22 ºC) (

FIG.3

). 

La sensibilidad del captador puede verse reducida si la temperatura del objeto a 

detectar está próxima a la temperatura ambiente. 

En la instalación del ViaTec se debe tener en cuenta que la activación se produce 

cuando la fuente de calor cruza sus haces de detección y, por lo tanto, si va en 

dirección al aparato, la detección es posible que se produzca a una menor distancia, 

ya que puede que no atraviese los haces, hasta que esté próximo al aparato. 

En el dibujo de la 

FIG.3

 las flechas indican la dirección del movimiento de la persona 

u objeto a detectar. 

La altura recomendada para la instalación del ViaTec está entre 1,1 y 1,7 metros. 

 

CONEXIONES: FIG.6 

 

PUESTA EN SERVICIO 

En la parte frontal del captador se encuentran los selectores 

LUX

TIME

  y un led 

(

FIG.4

). 

 

TIME

: El tiempo de retardo de desconexión es regulable de 10 segundos a 3 

minutos. La temporización comienza  después de la última detección de 

movimiento. 

 

LUX

: El interruptor de proximidad se gradúa para que actúe solamente cuando las 

condiciones de luz estén por debajo del nivel seleccionado. La luminosidad es 

regulable de 10 Lux (noche) a 2000

 

Lux (día). 

 

LED

: Se enciende cuando el dispositivo detecta presencia. 

Al conectar el equipo, se mantiene encendido durante 30 segundos, tras los cuales 

se apaga y queda en funcionamiento automático.

 

 

TEST 

-  Girar el selector 

TIME

  a su posición mínima (-) y el selector 

LUX

 a la posición   

(reaccionará en cualquier condición de luminosidad). 

Verificar que detecta moviéndose entre los límites del área de detección.

 

Una vez que se ha verificado que detecta, regular la luminosidad y el tiempo de 

desconexión deseado. 

 

AJUSTE DE LUMINOSIDAD: 

El ViaTec puede ser graduado de tal manera que actúe solamente cuando las 

condiciones de luz estén por debajo del nivel seleccionado. Girando el selector 

“LUX” hacia la posición ( ) reaccionará en cualquier condición de luminosidad. 

Girando hacía la posición ( ), solamente reaccionará en condiciones de baja 

luminosidad. 

 

AJUSTE DEL RETARDO DE DESCONEXIÓN: 

Girando el selector 

TIME

 el retardo de desconexión será:  

-  Tiempo mínimo de retardo de desconexión: 10 segundos. 

-  Tiempo máximo de retardo de desconexión: 3 minutos. 

Este tiempo se reinicia cada vez que el detector capta. 

 

Para que los cambios realizados en los potenciómetros de ajuste del equipo 

tengan efecto, es necesario salir del área de detección y esperar al apagado de 

la instalación.

 

La sensibilidad de captador puede verse reducida si la temperatura del objeto 

a detectar está próxima a la temperatura ambiente. 

Una vez finalizada la temporización el ViaTec tiene un periodo de inactividad 

de 2 segundos aproximadamente en los que no detecta

 

CARACTERÍSTICAS TÉCNICAS: 

Alimentación: 

230 V  50 Hz 

Consumo propio: 

5,4 VA   (1,1 W) 

Poder de ruptura: 

µ 4 A 230 V~ 

Salida relé 

Tecnología Paso por cero

 

Cargas máximas recomendadas: 

FIG.5

 

No apto para control de relés o contactores 

Rango de luminosidad: 

10 – 2000 lx 

Rango de temporización: 

de 10 segundos a 3 minutos. 

Ángulo de detección: 

120º a 22 ºC 

Campo de detección: 

aprox. 7 m a 22 ºC (

FIG.2

Temperatura de funcionamiento: 

-10 ºC  a  +40 ºC 

Grado de protección: 

IP20 según EN 60529 

ENG 

 

FLUSH MOUNTING MOTION DETECTOR

 

 

INSTRUCTIONS ON USE 

 

FIG.1 and FIG.2

  

1. 

LED 

2. 

Sensor 

3. 

Time adjustment 

4. 

Luminosity adjustment 

5. 

Frame SIMON Series 27 

 

 

DESCRIPTION 

The ViaTec motion detector  is especially designed for replacing a conventional 

switch in interior installations. 

The ViaTec captures the invisible infrared emissions from people and other heat 

sources without emitting any form of radiation. 

When a heat source moves in front of the ViaTec, its output circuit is activated. When 

it no longer captures the movement, it deactivates after a programmable time delay. 

The ViaTec only reacts when the light conditions are below the selected level. 

 

INSTALLATION AND MOUNTING 

WARNING:

  The installation and mounting of electrical appliances must be carried 

out by an authorised installer  

BEFORE CONNECTING, IT MUST BE ENSURED THAT THE CORRESPONDING 

CABLES DO NOT CARRY POWER.

 

The appliance is internally protected against interference by a security circuit. 

However, certain especially-strong electromagnetic fields may alter its operation, it 

therefore, must not be installed near inductive fields (motors, transformers, 

transformer substations and industrial machinery etc.), or high-frequency wireless 

signals (WIFI, telephony and signal inhibitor etc.). 

 

Flush-mounting in a mechanism box, avoiding highly reflective surfaces (liquids and 

marble etc.) within its detection field, elements subject to sharp changes of 

temperature (heating and cooling elements) or luminous sources. 

The ViaTec is specially designed to be installed in a conduit box with frames SIMON 

Series 27 (

FIG.2

). 

 

Detection area < 7 m (22 ºC) (

FIG.3

). 

The detector sensitivity may be reduced if the temperature of the object to be 

detected is close to the ambient temperature. 

The ViaTec installation must take into account that activation is produced when the 

heat source crosses the detection beams and therefore, if it is moving towards the 

appliance, it is possible that detection occurs at a closer distance because it will not 

cross the beams until it is close to the appliance. The arrows in the 

FIG.3

 drawing 

indicate the direction of movement of the person or object. 

The recommended height for ViaTec installation is between 1.1 and 1.7 metres. 

 

CONNECTIONS: FIG.6 

 

PUTTING INTO SERVICE 

The following selectors are located on the front part of the detector LUX, TIME and 

one LED (

FIG.4

). 

 

TIME

: The switch-off delay time is adjustable from ten seconds to three minutes. 

Timing commences after the last movement detection. 

 

LUX

: The motion detector is adjusted so that it only operates when light conditions 

are below the selected level. Luminosity is adjustable from 10 lux (night)to 2,000 

lux (day) 

 

LED

: This will light up when the device detects presence. 

When the equipment is switched on, the LED remains lit for 30 seconds, after which 

it goes out and the device is left in automatic operation. 

 

TEST 

Set the selector TIME to its minimum position (-) and the selector LUX to position   

(and it will react under any luminosity conditions). 

Check that it detects movement between the detection area limits. 

When detection has been verified, adjust the luminosity and the desired switch off 

time. 

 

LUMINOSITY ADJUSTMENT 

The ViaTec proximity switch can be adjusted so that  it only reacts when the light 

conditions are below the selected level. Set the selector "LUX” to the ( ) position 

and it will react under any luminosity conditions. Setting it to the ( ) position and it 

will only react under low luminosity conditions. 

 

ADJUSTING THE SWITCH-OFF DELAY 

Setting the selector TIME and the switch-off time will be:  

-  Minimum switch-off delay time: Ten seconds. 

-  Maximum switch-off delay time: Three minutes. 

This time is reinitiated each time the detector captures movement. 

 

In order for the changes made to the equipment adjustment potentiometers, it 

is necessary to leave the detection area and wait for installation to switch off.

 

The detector sensitivity may be reduced if the temperature of the object to be 

detected is close to the ambient temperature. 

When the ViaTec timing is completed, there is a period of inactivity of 

approximately two seconds in which it does not detect. 

 

TECHNICAL SPECIFICATIONS: 

Power supply: 

230 V  50 Hz 

Self-consumption: 

5.4 VA   (1.1 W) 

Breaking power: 

µ 4 A 230 Vac 

Relay output 

Passing through zero technology 

Maximum recommended loads 

FIG.5

 

It is not suitable for controlling relays or contactors 

Luminosity range: 

10 – 2000 lux 

Timing range: 

from 10 seconds to three minutes. 

Detection angle: 

120º to 22 ºC 

Detection field: 

approx. 7 metres at 22 ºC 

Operating temperature: 

-10 ºC to +40 ºC 

Degree of protection: 

IP20 according to EN 60529 

1,

1 -

 1,

7 m

ts

N

L

L

L

N

LUX

TIME

LED

FIG.1

2

4

6

8

2

4

6

8

180°

2

4

6

8

170°

160°

150°

140°

130°

120°

110°

100° 90°

10°

20°

30°

40°

50°

60°

70°

80°

200 VA

200 VA

800 W

500 VA

800 W

200 VA

200 VA

CFL

DOWNLIGHT

LED

FIG.3

FIG.4

FIG.5

FIG.6

3

1

2

4

22.5

46

54

46.5

5

FIG.2

OR

B

IS

 TE

C

NOL

OG

ÍA

 E

C

TR

IC

A

 S

.A

.

 Lér

ida,

 61

 E

-28020 M

adr

id T

el:

 (+

34)

 915672277;

 F

ax

:(+

34)

 915714006

 

OR

B

IS

 Ze

its

cha

ltt

ec

hnik

 Gm

bH

 Rober

t-Bo

sch

- S

tra

ße 3 D

-71088 Ho

lz

ger

ling

en T

elef

on 07031/

8665

-0 F

ax

 07031/

8665

-10 E

-m

ail:

 inf

o@

or

bis

-z

eit

sc

halt

tec

hnik

.de ht

tp:

//www.

or

bis

-z

eit

sc

halt

tec

hnik

.de

 

Отзывы: