Electric Connection
Eng
lish
19
Example:
* Theoretic peak values depend in practice on local circumstances and can result in lower values.
Local circumstances:
4 bar of pressure, 1” water line (210 l/min)
Question:
How many cattle bowls can be connected in addition?
Calculation:
210 l/min : 12 l/min = 17,5 pieces
17,5 pieces x 2 (
empirieal values
) = 35 pieces
Answer:
35 pieces of cattle drinking bowls can be connected.
21 l/min
16 l/min
12 l/min
6 l/min
1”
¾”
Flow rate of water
circuit
Mod. 671 Mod. 690
100 l/min
90 l/min
56 l/min
20 l/min
water flow
150 l/min
*
Tested with 4-5 bar
Mod. 700 Cattle/Horses
drinking
bowls
44 l/min
36 l/min
25 l/min
9,6 l/min
1,3 l/min
1,1 l/min
0,9 l/min
0,7 l/min
Pig
drinking
bowls
12 l/min
11 l/min
8 l/min
4 l/min
Pressure
4 bar
3 bar
2 bar
1 bar
water flow
water flow
water flow
water flow
Water flow quantity depends on the following conditions:
Water pressure, length of pipes and cross sectional area as well as the quantity of reduction
pieces and curves.
Experimental values
, based on field test, revealed that not all the drinking bowls are actionned at
the same time. This way the result has to be multiplied with
factor two.
Technical data:
two separate residual current devices (RCD) two-pole
30 mA and four-pole 30 mA.
A damaged heating or pump can cause that the residual current circuit breaker triggers and the
heating unit and the pump are out of function. This leads that the water supply line risks to
freeze due to a cold outside temperature.
Special and corresponding steps have to be taken at the spot by the user to protect it
against freezing: e.g. frost protection heating cables, warning system, etc.
Heating Unit must be used with
Water pressure range 1 - 4 bar
Water connection entry 1”
Water connection exit 1”
Size l,w.h 70 x 60 x 30 cm
Weight 33,5 kg
Connections
3 x 1,5 mm² - Voltage supply 1x230 V +/-10% 50 Hz
Connections Heater 5 x 1,5 mm² - Voltage supply 1x400 V +/-10% 50 Hz
Output Pump 230 V AC stage 3 = 1,73 A = 400 W
Output Heater PWM 0-3000 W
eating
Controller / Pump
STB 90°C opener/h
Dust/water protection IP 44
Heating range 0-40° C
Determination of Quantity of Drinking Bowls
Heating Unit Mod. 311
must be fix installed and permanently wired.
Use distribution box of min IP 54. Local norms and regulations must be
respected! According connection diagram, observe VDE 0100!
All installation, maintenance and inspection works of the unit must be carried out only
by an authorised and qualified specialist.
210 l/min
*