Page 41
5-13
#7040748 - Revision A - September, 2016
MODEL UW-24
MODEL UW-24
Component Removal
Compressor Removal
The compressor is located at the back of the unit tray.
NOTES:
The refrigerant valve with the filter-drier must be
•
replaced when replacing a compressor.
After capillary tube separates, check tubing for
•
internal burrs. If burrs exist, rescore the capillary
tube.
Sererate the unit to access the compressor, then (See
Figures 5-23):
1.
Disconnect compressor electricals.
2.
With a tube-cutter, cut suction tube and discharge
tube approximately two inches from the compres-
sor.
3.
Remove nuts from compressor mounting studs and
lift compressor off of mounting studs.
Condenser Removal
The condenser is located at the front right of the unit
tray, and held in place with a bracket and pop-rivets
passing up from under the unit tray into the condenser
bracket and clamps.
NOTES:
The refrigerant valve with the filter-drier must be
•
replaced when replacing a condenser.
After capillary tube separates, check tubing for
•
internal burrs. If burrs exist, rescore the capillary
tube.
Sererate the unit to access the condenser, then (See
Figures 5-24):
1.
With a tube-cutter, cut inlet tube and outlet tube
approximately three inches from the condenser.
2.
Flex the bracket at the rear of the condenser off of
the condenser.
3.
Drill out the 1/8” pop-rivets from the front brackets
4.
Lift the condenser out of the unit.
Figure 5-23. Compressor Removal
Suction
Discharge
Compressor
Figure 5-24. Condenser Removal
Clamp
Bracket