Suburban SW4DEFA Скачать руководство пользователя страница 11

PARTS ILLUSTRATION AND REPLACEMENT PARTS LIST

PARTS LIST FOR MODELS:  SW4DRA • SW4DFA • SW4DERA • SW4DEFA

SW6DRA  •SW6DFA  •SW6DERA  •SW6DEFA 

 

Only factory authorized parts are to be used. 

Do not attempt to repair defective parts.

When ordering repair parts from your dealer or a distributor, always give the following information:     

 

1. 

Part Number (Not Item No.)

 

2. 

Part Description

 

3. 

Model No. and Serial No. of your Heater

ITEM 

NO. DESCRIPTION

PART 

NUMBER

1

Module Board

521114

3

Cover, Module Board

090613

6

Bushing, Snap 1/2"

070270

7

Bushing, Strain Relief 5/8"

230216

8

D.C. Junction Box Assembly

090517

10 Flue Collector Assembly Complete

102936

12 Valve Pressure Relief

161339

13 Screw, #8 x .375 w/ seal

122289

15 Cover, Thermostat/Hi-Limit

090562

18 Grommet

070874

20 Bracket, Electrode Mounting

063187

21 Electrode

232258

26

Burner Assembly with orifice

011138

27 Air Shutter Asembly (Main Burner)

010857

28 Electric Element with Gasket

520831

29 Anode

233514

31 Connector, Electric (Gas valve 

wire)

521264

34 Gas Fitting

170374

35 Bracket,Valve Mounting

063243

36 Valve, Gas (LP)

161164

37 Manifold, Outlet

171420

38 Screw #8 x .250 w/ seal

122288

39 Screw #8-32 x 3/8

121934

41 Switch Assembly, 12 V.D.C.  

T-Stat/Hi-Limit

232319

ITEM 

NO. DESCRIPTION

PART 

NUMBER

42 Switch Assembly, 220 V.A.C.  

T-Stat/Hi-Limit

232317

45 Grommet, Gas Inlet

070989

47 AC Power Cord Assembly

090703

48 Nut, 10-24 Keps (Green)

121576

50 Foam Jacket (6 Gallon)

521267

Foam Jacket (4 Gallon)

521266

51 Switch, Lamp and Plate Assembly

232589

52 Screw, 8mm - 4.0 x 1/2 Hex 

Washer Head (2 Required)

121943

53 Burner Bracket

063444

55 1/4 Loxit Nut (Manifold to Burner)

171463

56 1/4 Loxit Nut (Manifold to Valve)

171463

57 Electrode Wire (Not Shown)

232456

59 Cover, Element

090681

61

Door,  Radius  Corner  (not  shown)                                                                  

(Only Radius Corner Intermediate 

Frame)

6282AAW

6282APW

6282AEB

62

Door,  Flush  Mount  (not  shown)                                                                  

(Only Flush Mount Intermediate 

Frame)

6281APW

6281AEB

6281AAW

63 Plug Break Through

233309

65 Connector, Electric (electrode wire) 521265
66 Gasket, Screw Thread

072119

11

Содержание SW4DEFA

Страница 1: ...H ANY ELECTRICAL SWITCH DO NOT USE ANY PHONE IN YOUR BUILDING OR RV IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBORS PHONE FOL LOW THEIR INSTRUCTIONS FREEZE WARNING DRAIN HEATER IF SUBJECTED TO FRE...

Страница 2: ...ion heater into framed opening as illustrated D On mesa or yoder type sidewalls flatten the wall area around the opening E Caulk around framed opening trailer skin as illustrated F Apply a bead of sil...

Страница 3: ...connections are tight and in compliance with codes See Making Electrical Connections D The following is information regarding Hot Water Services and corrosion of the tank in Australia The single bigg...

Страница 4: ...om the valve until it stops 5 Release handle on P T Valve it should snap closed 6 Close tap and turn on cold water supply as the tank fills the air pocket will develop Repeat this procedure as often a...

Страница 5: ...provided 2 Turn off all electric power to the appliance 3 Turn OFF gas supply 4 Wait five minutes for gas to clear the area If you smell gas then STOP Follow instruc tions in item B of the safety info...

Страница 6: ...EAL DOOR FRAME TO SKIN WATER TIGHT SEE DETAIL A Figure 2B Models SW4DRA and SW6DRA Figure 2A Models SW4DERA and SW6DERA A FRAMED OPENING DETAIL A SPECIAL SCREW CONTROL HOUSING GASKET DOOR LATCH RADIUS...

Страница 7: ...S FRAME TO COACH WALL FLUSH MOUNT DOOR FRAME A INTERMEDIATE FRAME WITH GASKET FRAMED OPENING DETAIL A SPECIAL SCREW CONTROL HOUSING GASKET CONTROL HOUSING GASKET OR CAULK AROUND OPENING TO SEAL CONTRO...

Страница 8: ...CTORY WIRING FIELD WIRING DISCONNECT POWER SUPPLY BEFORE SERVICING THERMOSTAT AND HI LIMIT UNDER ACCESS COVER 1 3 4 6 CAUTION DO NOT HI POT DIELECTIC HIGH VOLTAGE TEST THIS UNIT AFTER INSTALLATION TO...

Страница 9: ...ILL NOT COME ON NOT ENOUGH HOT WATER WATER TOO HOT POSSIBLE CAUSE XXXXX Possible malfunction of the bottled gas regulator XXXXX Main burner orifice too small or clogged XXXXX Check thermostat position...

Страница 10: ...7 6 27 42 28 59 6 63 47 38 10 12 13 13 13 13 13 13 66 66 66 Figure 12 SW4DERA AND SW6DERA SW4DEFA AND SW6DEFA MODEL SERIAL NO PLATE 12 20 21 53 26 39 35 38 34 37 55 56 36 45 41 29 50 51 1 3 52 15 8 4...

Страница 11: ...ment with Gasket 520831 29 Anode 233514 31 Connector Electric Gas valve wire 521264 34 Gas Fitting 170374 35 Bracket Valve Mounting 063243 36 Valve Gas LP 161164 37 Manifold Outlet 171420 38 Screw 8 x...

Страница 12: ...y or diagnosis without repair 3 Damage or repairs required as a consequence of faulty or incorrect installation or application not in conformance with installation instructions 4 Failure to start or o...

Отзывы: