Suburban SA25N Скачать руководство пользователя страница 9

17

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REM EDY

Ignition failures 

(continued)

5. Burner cycles off and glo-bar comes

on immediately, check the following:

5. A. Check flame sensing probe. Be sure probe is

positioned in the burner flame and glowing
cherry red. Check wire and wire connections
at probe and ignition control.

B. If wire and wire connections okay, check for

voltage across brown and orange wires at
ignition control. If no voltage, replace ignition
control.

C. If voltage present, check wiring and wire

connections at valve.

D. If wire and wire connections okay, replace

valve.

Excessive noise

1. Blower out of balance
2. Motor hums

1. Replace blower
2. Replace motor

Main burner will not cycle off

1. Thermostat setting
2. Gas Valve stuck open

1. Check thermostat
2. Check gas valve. If stuck open, replace.

Do not attempt to repair valve!

Furnace will not operate

1. Wiring connections or shorts

1. Check all wiring to assure proper connection or

detect possible shorts.

18

Figure 20 - Wiring Diagram (25,000 BTU/Hr Model)

Figure 21 - Wiring Diagram (40,000 BTU/Hr Model)

WIRING DIAGRAMS

REPLACEMENT
PARTS

Note:

 Use only original replacement parts.

This will protect your warranty coverage for
parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product.
If they can't supply original replacement
part(s), call:

 Suburban Manufacturing Company

Customer Service Department

(423) 775-2131, Ext. 1

Have ready:

your name

your address

model and serial number of your furnace

how furnace was malfunctioning

type of gas used (propane/LP or natural
gas)

purchase date

Usually, we will ask you to return the defec-
tive part to the factory.

PARTS NOT UNDER
WARRANTY

Contact authorized dealers of this product.
If they can't supply original replacement
part(s), either contact your nearest gas
company or call :

 Suburban Manufacturing Company

Customer Service Department

(423) 775-2131, Ext. 1

When calling Suburban, have ready:

model number of your furnace

the replacement part number

part description

number of parts required

SERVICE HINTS

W hen Gas Pressure Is Too Low

glo-bar glows, but burner will not ignite

W hen Gas Quality Is Bad

burner will not stay lit

burner will produce flames and soot

You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
gas supplier.

TECHNICAL SERVICE

You may have further questions about in-
stallation, operation, or troubleshooting. If
so, contact:

Suburban Manufacturing Company
Customer Service Department
Post Office Box 399
Dayton, Tennessee 37321
(423) 775-2131, Ext. 1
Fax: (423) 775-7015

Содержание SA25N

Страница 1: ...on or near the appliance Never place any objects on the furnace Surface of furnace becomes very hot when running furnace Keep children and adults away from hot surface to avoid burns or clothing ignit...

Страница 2: ...re you have all items below electric drill drill bits Phillips screwdriver hammer pipe wrench stud locator or small finishing nails equipment shutoff valve supplied test gauge connection see Figure 15...

Страница 3: ...re no pipes wiring or anything else that wouldinterferewith installing thermostat Do not mount thermostat to stud If there are any obstructions choose a new location 3 Provide two 18 gauge insulated s...

Страница 4: ...iquid soap and water to all joints Bubbles forming show a leak Correct all leaks at once 13 Caulk around pipe or nipple This pre vents cold air entering knockout hole 8 INSTALLATION Continued Providin...

Страница 5: ...15 Install an equipment shutoff valve in an accessible location The equipment shutoff valve is for turning on or shutting off the gas to the appliance Apply pipe joint sealant lightly to male threads...

Страница 6: ...explosion may result causing propertydamage personal injury or loss of life A This appliance does not have a pilot It is equipped with an ignition device which automatically lights the burner Do not...

Страница 7: ...a qualified service person Furnace may need more frequent cleaning due to excessive lint from carpeting bedding material pet hair etc CAUTION Labelall wiringprior to disconnection when servicing contr...

Страница 8: ...e is established the sensing probe will sense the presenceofburnerflame and open the glo bar circuit The glo bar will then stop glowing It is important to determine the type of problem being experienc...

Страница 9: ...ty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call Suburban Manufacturing Company Custo...

Страница 10: ...MODEL KEY NO PART NUMBER DESCRIPTION QTY KEY NO PART NUMBER DESCRIPTION QTY 1 121357 Screw 6 x 5 8 4 14 021175 Combustion Chamber Radiation 2 232773 Module Board 1 Shield Assembly with Gasket 1 2A 232...

Страница 11: ...N QTY 1 350086 Room Air Wheel 1 15 390296BK Combustion Air and Motor 2 121252 Screw 10 x 3 8 5 Cover Assy Housing 1 3 121247 Screw 2 56 x 5 8 2 16 070386 Combustion Air Housing Gasket 1 4 230510 Micro...

Страница 12: ...ew 6 x 3 8 2 17 230560 Limit Switch 1 2 231950 Flame Sensing Probe 1 18 062563 Ignition Control Mounting 1 3 063018 Glo Bar Retainer 1 19 232773 Module Board 1 4 120158 Screw 8 x 3 8 6 19A 232774 Wiri...

Страница 13: ...10 24 x 1 2 2 2 121252 Screw 10 x 3 8 8 16 070362 Universal Bushing 1 3 350088 Room Air Wheel CW Rotation 1 17 070406 Combustion Air Housing Gasket 1 4 390328BK Room Air Blower Housing 18 120158 Scre...

Страница 14: ...XCLUSIVE AND MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTRIBUTOR DEALER OR OTHER PERSON WHOMSOEVER ALL REPLACEMENT PARTS ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WA...

Отзывы: