A
4"
3 1/8"
18"
E
MIN.
C
MINIMUM DISTANCE TO COMBUSTIBLE SURFACES
DIRECTLY ABOVE COOK-TOP 24"
*D
WALL
*C-SEE UL LABEL
*
13" MAXIMUM OVERHEAD
CABINET DEPTH
B
REAR
FRONT
Figure 2
20 lbs) and weight of cooking unit (20 lbs.) from 100 lbs. The weight
label should sa no more than 60 lbs. can be put on the counter top.
c.
The surface material for the counter tip must be rated for a minimum
of 200° F continous coperation temperature with the maximum weight
applied.
d.
Minimum clearances from combustible walls above and below the
counter top must be adhered to during operation.
e.
The OEM must provide a warning label placed on the counter top
that requires the unit to be cooled a minimum of 30 minutes after use
before storing.
f.
During storage, a clearance of 1" must be maintained from the top
surface of the unit.
g. NOTE:
The gas must be turned "OFF" and disconnected when
stored.
SAFETY INFORMATION