SUBMERSIBLE SYSTEMS HEED 3 Скачать руководство пользователя страница 4

 

 

ALL INFORMATION IS PROPRIETARY AND MAY NOT BE COPIED WITHOUT WRITTEN PERMISSION OF SUBMERSIBLE SYSTEMS. 

5/20 

 

 

G:\Mktg\MILT\Heed 3 tech manual.hose

 

 

11. 

Depress the second stage Purge Button until air flow can no longer be heard and the hose is depressurized. 

12. 

You must turn the knurled ring on Adapter to open (counter-clockwise) position to relieve pressure in the 
Adapter. 

 

NOTE:  You will not be able to remove the Adapter from Refill Port until this is done. 

13. 

Remove Adapter from SCUBA cylinder and HEED. 

14. 

Replace rubber cover on Refill Port. 

 
MOUNTING INSTRUCTIONS:

 

Optional HEED 3 Holster is designed to attach to a modular style vest (MOLLE).  

 

1. 

Weave the 2 straps on the back of the modular holster through the webbing of vest (left side recommended) 
and snap into place. 

NOTE:  It is important that the operator be able to grip the regulator having sufficient clearance for a pull of at 
least 6 inches. 

2. 

Place unit in Holster and attach flap securely over the regulator ensuring velcro is fully engaged. 

3. 

Attach Mouthpiece Cover. 

4.  

Affix the included small velcro tab located on the metal ring to another web to help secure the holster. 

 
 

PRE-USE CHECK:

 

 
1. 

Check for obvious physical damage, broken or loose parts.  Do not use if damaged. 

2. 

Turn the system on by turning the On/Off Valve counter-clockwise until it is completely open. 

3. 

Visually check Dial Gauge for needle to be within green zone.   Refill if necessary. 

4. 

Push Purge Button down and release.  Purge Button should move up and down freely.  To maintain full 
pressure do not purge unnecessarily.   

 
 

USING HEED: 

 

 
1. 

Grab HEED regulator head and pull until Hose is completely out of the Holster.  This action will release the 
Mouthpiece Cover. 

2.  

Place the HEED regulator into user’s mouth. 

3. 

If the system is used underwater press purge button lightly or exhale sharply to expel water from the regulator 
prior to inhalation. 

 

CAUTION:  Failure to purge the HEED regulator before inhaling will result in swallowing water. 

4.  

Continue to inhale and exhale to a safe and normal rate of ascent.  Take small, slow, steady breaths to 
maximize the duration of air supply.  

NOTE:  The HEED utilizes a balanced regulator which means it will provide air in any orientation including the 
regulator being upside down or sideways. 

CAUTION:  If HEED is used until completely empty underwater, it should be referred for five year 
service. 

5. 

When done using system, turn the On/Off Valve clockwise to turn off. 

 
 
 
 
 
 
 
 
 

Отзывы: