background image

 
 
   

 

 

 
 

Industrial Managed Ethernet Switch Hardware User Manual 

 

 
 

   

RPT-2010G-2F(-T)-X2  

 
Quick Installation Guide 

Version 1.0.0 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Subject Link Inc 
9F-1, No. 77, Sec 4., Nangjing E. Rd, Taipei City, 10580, Taiwan, R.O.C. 
Tel: +886 935 672 398 
Mail: 

[email protected]

 

Web: www.sbjlink.com 

Содержание RPT-2010G-2F

Страница 1: ...t Switch Hardware User Manual RPT 2010G 2F T X2 Quick Installation Guide Version 1 0 0 Subject Link Inc 9F 1 No 77 Sec 4 Nangjing E Rd Taipei City 10580 Taiwan R O C Tel 886 935 672 398 Mail sales sbjlink com Web www sbjlink com ...

Страница 2: ...ion 2 Dimensions 2 Top View 3 LED Instruction 3 Reset Button 4 USB Port 4 Earth Grounding 4 Hardware Installation 5 SFP Cabling 5 Wiring Power Inputs 7 Wiring Fault Alarm 7 Wiring Digital Inputs 7 Double Secure Power Input Fault Alarm 8 Mounting 9 Installation Steps 10 Specification 11 ...

Страница 3: ... 12Mbits Packet Buffer supported Power Input Redundant 12 48VDC power Temperature Standard operating temperature 10 C 60 C 14 F 140 F Extended operating temperature 40 C 75 C 40 F 167 F Storage temperature 40 C 85 C 40 F 185 F Mechanical Construction Class IP30 protection DIN Rail Mounting Optional Wall Mounting PACKAGE CHECK LIST The RPT 2010G 2F T is shipped with the following items Ensure that ...

Страница 4: ...2 Hardware Description FRONT PANEL INSTRUCTION The following picture is the front panel for RPT 2010G 2F T DIMENSIONS WxHxD 72x145x118 mm ...

Страница 5: ...Ring Master is not on the device Ring Green On The Ring protocol is enabled and works normally Flashing The Ring protocol is enabled but works abnormally Off The Ring protocol is disabled Interface Status LEDs LED Color Status Description SFP Slot P9 to P10 1000M Green On The 1000Mbps link of the fiber port is active Flashing Data is transmitted on the fiber port at 1000Mbps Off The 1000Mbps link ...

Страница 6: ...wing features Backup Restore Configurations Auto Load configuration from USB Auto Backup configuration to USB Save system logs to USB EARTH GROUNDING The earth grounding and cautious wire routing are helpful to suppress the effects of noise from electromagnetic interference EMI The switch has to be installed on a well grounded surface for instance a metal panel The location of earth ground screw i...

Страница 7: ... SFP 1000LX AXCEN Single Mode 10km AXGE 1354 0533 SFP 1000LX IT AXCEN Single Mode 10km AXGD 1354 0531 SFP 1000LX DD AXCEN Single Mode 10km 1 25Gbps 1000Base BX Single Fiber Bi Directional SFP AXGE 3454 0531 SFP 1000BX10 D4 AXCEN Single Mode 10km AXGE 1254 0531 SFP 1000BX10 U4 AXCEN Single Mode 10km 10Gbps SFP For 10G Model Only LM28 H3S TC N EA 10Gbps APAC Multi Mode 300m LE38 H3S TIN 10Gbps APAC ...

Страница 8: ...sert SFP Module 1 Insert the SFP module A triangle is available on the switch and SFP module 2 Push the SFP module down Remove SFP Module 1 Press and remove the SFP cable 2 Open the SFP module and remove it ...

Страница 9: ...ews to prevent the wires from loosening 3 The relay will detect the power and link failure 4 Users can connect the relay to an alarm and buzzer so that when the relay forms an open circuit the users will be notified WIRING DIGITAL INPUTS 1 Insert the positive and negative wires into the right two contacts of the 4 contact terminal block DI 2 Tighten the screws to prevent the wires from loosening 3...

Страница 10: ...ive input is connected but double secure is supported to prevent the unnotified failure of power from one of the negative inputs Should one of the negative power inputs fail the system will detect the failure NOTE the system will trigger an event occurrence only if the user has set the fault alarm or event log for power ...

Страница 11: ...switch b Insert the top of the DIN Rail bracket to the DIN Rail track c Pull down the DIN Rail bracket to the DIN Rail track and check if it is mounted tightly on the DIN Rail track Wall Mounting a Remove the DIN Rail bracket b Screw the wall mount kits to the switch ...

Страница 12: ...t us for assistance To install the switch on the wall refer to the Wall Mounting section 4 Power On To power on the switch users must prepare a power supply and wire the power input Refer to the Wiring Power Inputs section The power LEDs are described in the LED Instruction section 5 Connect To connect to the switch users need a RJ45 cable Insert the RJ45 cable into one of the switch ports and ins...

Страница 13: ... Protocol IEEE 802 1Q VLAN Tagging IEEE 802 1ad Stacked VLANs IEEE 802 1p Class of Service IEEE 802 1X Network Authentication IEEE 802 1AB LLDP IEEE 1588 PTP Processing Type Store and Forward Transfer Rate 14 880pps for Ethernet port 148 800pps for fast Ethernet port 1 488 000pps for gigabit Ethernet port Transmission Distance Up to 100M Fast Ethernet Transmission Speed Up to 1000Mbps Switch Prope...

Страница 14: ...or state 0 Max input current 8mA Button Multiple functions reset button Serial Console 1x RS232 in RJ45 connector with console cable 115 2Kbps 8N1 Storage 1x USB 2 0 storage for firmware update configuration backup restore boot up and syslog Power Requirements Operation Voltage 12 48VDC redundant dual inputs Connection 1x removable 4 contact terminal block Power Consumption 0 51A 24VDC Protection ...

Страница 15: ...ass A EMS IEC61000 4 2 ESD IEC61000 4 3 RS IEC61000 4 4 EFT IEC61000 4 5 Surge IEC61000 4 6 CS IEC61000 4 8 Magnetic Field Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 Green RoHS Compliant Certifications UL 60950 1 62368 Pending IEC 61000 6 2 IEC 61000 6 4 EN 50121 4 MTBF 100 000 hours Warranty 5 Years Subject Link Inc 9F 1 No 77 Sec 4 Nangjing E Rd Taipei City 10580 Taiwan R...

Отзывы: