4. OPERATING PROCEDURES
(See Fig.
3
3
,
4
4
)
1. STARTING THE GENERATOR
Check the oil level before each operations
as outlined on page 5.
CAUTION
■
■
Do not run the starting motor over 5
seconds continuously.
If the engine fails to start, return the
key to the "
"(ON) position and wait
about 10 seconds then start again.
■
■
Do not turn the key switch to "
"(START)
position when the engine is running to
prevent damage of starting motor.
■
■
When starting the engine by recoil starter,
set the key switch at the "
"(ON)
position and pull the starter handle.
CAUTION
(a) Make sure the appliance is disconnected.
(b)Turn engine switch to "
"(CHOKE) position.
(When engine is warm or temperature is high,
start engine with the switch at "
" (OPEN)
position.) (See Fig.
3
-
q
)
q
"
" (CLOSE)
w
"
" (CHOKE)
(c)
[Recoil starter model]
Pull the starter handle slowly until passing the
compression point (resistance will be felt), then
return the handle to its original position and pull
briskly. (See Fig.
3
-
w
)
q
RECOIL STARTER HANDLE
w
PULL BRISKLY
(d)After starting, allow the starter handle to return to
its original position with the handle still in your
hand.
(e)
[Electric starter model]
Insert the key into the key switch and turn it
clockwise to the "
"(ON) position to start the
engine.
Then turn the key further to the "
"(START)
position. The engine will be started by starting
motor.
■
■
Do not connect defective appliances
including lines and plugs.
■
■
Be sure appliances are not connected
to generator when starting up.
Starting the generator with an
appliance connected could result in
damage to the generator and/or
appliance and in personal injury.
CAUTION
NOTE
When engine fails to start after several attempts,
repeat the starting procedures mentioned
above with the engine switch placed at
"
" (OPEN) position.
(f) After 20 to 30 seconds of warm-up is completed,
turn the engine switch to "
" (OPEN) position.
(See Fig.
3
-
e
)
q
"
" (CHOKE)
w
"
" (OPEN)
(g) By changing over the LE display in the multi
monitor into the "voltage" indication, make sure
the generating voltage is the normal level
(approx.230V).
NOTE
If no generating condition is found out,
please consult nearest ROBIN dealer.
RG4300iS en̲GU7045 10.6.8 4:35 PM ページ7
Содержание RG3200iS
Страница 1: ...ISSUE EMD GU7130 RU 3ZZ9990551 PRINTED IN JAPAN January 2011 Original ...
Страница 3: ...3 4 5 6 2 3 4 2 1 3 6 1 1 1 2 1 2 1 1 1 2 RG4300iS en GU7045 10 6 8 4 35 PM ページ02 ...
Страница 4: ......
Страница 5: ......
Страница 10: ...4 EN GB GB GB GB GB GB GB GB GB GB GB GB GB GB GB RG4300iS en GU7045 10 6 8 4 35 PM ページ4 ...
Страница 28: ...ISSUE EMD GU7130 RU 3ZZ9990551 PRINTED IN JAPAN January 2011 Original ...