SET UP

6

HOOK UP

1. FILL/ ADD SMOKE PRODUCING FLUID

Remove Fluid Fill Plug with hex key
Pour Subaru-Approved Smoke Agent into Fluid 
Fill Port until fluid level is near top of fill port
Replace Fluid Fill Plug
           
         Do not overfill
           Takes up to 2  fluid ounces to refill when empty   

         

          Do not use dye or UV dye in any Subaru
          Intake, Exhaust, or EVAP system because it  

          may coat or harm critical sensors

2. INSTALL HANDLE-HOOK

Use a wrench to tighten jam nut

!     

3. CONNECT TO POWER

This machine runs on a fully-charged 12-Volt battery
Connect red lead (+) to battery’s positive terminal
Connect black lead (-) to chassis ground
       
 

Do not connect to battery charger or jumper box

POWER INDICATOR:

         Green Light: Machine has adequate power
         Flashing Green Light: Improper Power, Power is too high or too low
         No Light: No Power, See Troubleshooting   

!

!     

Содержание 697-95-070

Страница 1: ...697 95 070 OPERATION MANUAL Manufactured in California USA...

Страница 2: ...CONTENTS Specifications 1 Reference Guide Front 2 Reference Guide Back Safety 3 Accessories Incuded 4 Set up 6 Troubleshooting 7 Warranty 8 Support 9...

Страница 3: ...0 F to 140 F 1 C to 60 C Operating Humidity No Restrictions Operating Altitude No Restrictions Smoke Output Hose 10 ft 3 m Power Supply Cables 15 ft 5 m Operating Modes Smoke Test Cycle Air Only Test...

Страница 4: ...ressure into system by opening the flow control valve Close flow control valve to lock out system for pressure decay testing D Power Indicator Light Green light indicates adequate power E Smoke Test B...

Страница 5: ...Follow all safety precautions SAFETY PRECAUTIONS All diagnostic work should be performed with the engine off Do not leave a vehicle unattended while equipment is connected or operating When working w...

Страница 6: ...l tests per bottle IMPORTANT Contains NO Dye Contaminants EVAP Service Port Adapter Kit 697 96 0003 Schrader Valve Removal Tool and EVAP Service Port Adapter Halogen Inspection Light 697 96 0011 Brigh...

Страница 7: ...697 15 0085 To introduce smoke pressure through fuel filler neck Fuel Cap Adapter Dual Start 697 15 0089 To introduce smoke pressure through fuel filler neck EVAP Line Sleeve Sealing Cap 697 80 0025...

Страница 8: ...y Subaru Intake Exhaust or EVAP system because it may coat or harm critical sensors 2 INSTALL HANDLE HOOK Use a wrench to tighten jam nut 3 CONNECT TO POWER This machine runs on a fully charged 12 Vol...

Страница 9: ...r or Red Light Flashing Open Circuit internal component Contact Technical Support No Air Flow Open the flow control valve Check hoses are not kinked or pushed into machine Not Enough Smoke Check Fluid...

Страница 10: ...ucts are only to be used by persons having skill and knowledge in the automotive repair field and improper use or maintenance may cause serious injury In no event shall Redline be liable beyond replac...