Page 7
International Dual Fuel (ICBDF) Series
International Dual Fuel (ICBDF) Series
Installation Information
2-2
#814889 - Revision A- July, 2010
INSTALLATION INFORMATION
This section of the manual covers some of the installation issues that a service technician may need to know when
servicing a Wolf ICB Dual Fuel Range. If additional installation information is needed after reviewing this section of
the manual, please refer to the Installation Guide or contact the Wolf Appliance Customer Service Department.
Electrical Requirements
Required Electrical Supply:
•
230 volts AC, 50/ Hertz, 15 ampere fused electrical supply for 36” units.
•
230 volts AC, 50/60 Hertz, 28 ampere fused electrical supply for 48” and 60” units.
•
Separate circuit serving only this appliance.
•
Installation site must be equipped with a properly grounded receptacle.
Minimum Electrical Wire Size:
30” and 36”
•
L1 - 0.82mm2 (18 AWG)
•
Neutral - 0.82mm2 (18 AWG)
•
Ground - 0.82mm2 (18 AWG)
48” and 60”
•
1 and L2 - 2.08mm2 (14 AWG)
•
Neutral - 2.08mm2 (14 AWG)
•
Ground - 2.08mm2 (14 AWG)
The unit is designed with a terminal block on the rear of the range. The terminal block allows for 3-wire or 4-wire
installation. For a 4-wire installation, the ground strap from the unit to the terminal block must be cut. Two concen-
tric knockouts
(on the terminal block)
, are provided to allow a certified electrical contractor to wire the range directly
to a junction box.
The terminal block will also accept an appliance power cord. The power cord must be sized correctly for the units
voltage and amperage.
Please refer to state, municipal and local codes for the best means to connect the appliance to the electrical
power supply.
A SHOCK HAZARD COULD EXIST IF THE ELECTRIC RECEPTACLE OR THE POWER CORD ARE NOT PROP-
ERLY GROUNDED AND POLARIZED.
The appliance may experience ignition problems if not properly grounded and polarized
.