background image

9

12

+

-

BUZZER 

To SZ-B75

(10Vdc, 10mA max)

Low T

empT

rip Lamp

or Other Load (5A

 max)

Compressor or

Contactor

or Heater

 8(3)A max)

Caution : Wiring Shown for 230Vac Loads Only.

12

11

15

16

Installation :

 Fixing and dimensions of panel models:

To fix the unit, slide the fastener  1  through the guides  2  
as per the position shown in the figure. Move the fastener in 
the direction of the arrow, pressing tab  3  it permits to move 
the fastener in the opposite direction of the arrow. Once the 
controller has been connected, they should be covered with 
the lid  4  Silicon sealant should be applied along the 
perimeter of the panel cut out or a rubber ‘O’ ring supplied
before the unit is fitted to obtain IP65 grade.

Alarm (Buzzer) :  

Only use SZ-B75 buzzer with SZ-

7512-P series controller. Use of any other type of result 
in permanent damage to the controller and may cause 
personal injury.

 

Controller 

:Controller should be installed in a place 

protected by vibration, water and corrosive gasses and 
where ambient temperature does not exceed the 
values specified in the technical data.

Probe :

To give a correct reading, the probe must be 

installed in a place protected from thermal influences, 
which may affect the temperature to be controlled. 

CAUTION

WIRING:

 The probe and its corresponding wires should

 

never 

be installed in a conduit next to control or power

 

supply lines. 

The electrical wiring should be done as shown in the diagram. 
The power supply circuit should be connected to a protection 
switch. The terminals admit wires of upto 2.5sq mm.

WARNING:

  Improper wiring may cause irreparable damage 

and personal injury. Kindly ensure that wiring
is done by qualified personnel only.

Maintenance:

 Cleaning:  Clean the surface of the controller 

with a soft moist cloth. Do not use abrasive detergents, petrol, 
alcohol or solvents.

Notice: 

The information in this document is

 

subject

 

 to change 

in order to improve reliability , design or function without prior 
notice and does not represent

 

a commitment on the part of the 

company. In no

 

event will the company be liable for direct, 

indirect, special, incidental or consequential damage arising out 
of the use or inability to use the product or documentation, even 
if advised of the possibility of such damages. No part of this 
manual may be reproduced or transmitted in any form or by any 
means without the prior written permission of the company.

GASKET

13

GASKET

PANEL

Side Lock

CONTROLLER

14

SZ-7512-P

prg

SET

O

C

RST

3

1

4

2

34.5mm

71mm

19mm

10mm

MAX

71mm

29mm

Panel cutout

PANEL

Suggested Wiring Diagram

PROBE

230V

NC

C

NO

RELAY

11

10

Technical data :

 

 

Display

14.2 mm (0.56") LED.

Data storage

Non-volatile EEPROM memory

Power input

:

 /-10%, 50Hz/60Hz. Others on 

  request.

O

O

Operating temp.

 5 C to 50 C(non-condensing).

O

O

Storage temp

-20 C to 70 C(non-condensing).

Output 

1 SPDT relay 8(3)A, 250Vac

Input 

:

 NTC probe, SZ-N75

O

O

Range 

:

 -50 C to 50 C

O

Resolution

:

 1 C

O

Accuracy 

:

 +/-1 C

O

O

Probe tolerance at 25 C :

 +/-0.3 C

Alarm (buzzer) : 

SZ-B75, 10Vdc, 10mA

Housing  

Black ABS plastic

.

Front cover 

:

 Polycarbonate plastic

.

Dimensions

 :

 Front - 75 x 34.5 mm,

 

  

  Depth 71 mm (w/o back lid).

Panel Cutout

:

 29mm x 71mm

Mounting 

:

 Flush panel mounting with fasteners. 

Protection 

Front panel is water proof & IP 65 rated .

Connections 

:

 Screw terminal blocks

  

2.5

 

sq

.

mm

 

wire terminal only

Содержание SZ-7512-P

Страница 1: ...he above mentioned mechanical thermostats i e relay will go off when the set point is achieved and the same can be restarted only if the differential is reached and the RST key is pressed 1 INDEX 2 Para Page Description P5 LP AL FS EP 3 4 5 6 7 8 9 10 12 13 14 To set the Set Point of the controller How to set other parameters Probe calibration Keypad lock Alarm to activate buzzer Restore factory d...

Страница 2: ...eter 0 1 1 Function To activate deactivate alarm To change the AL parameter press the SET key Use the UP DOWN keys to set alarm on or off Once set to on the buzzer will come on incase the temperature is equal to the set point 1 Activates Buzzer 0 Deactivates Buzzer Note Alarm will be ON in probe fail condition irrespective of AL parameter Min Max Fac FS Parameter Function To restores default setti...

Страница 3: ...RNING Improper wiring may cause irreparable damage and personal injury Kindly ensure that wiring is done by qualified personnel only Maintenance Cleaning Clean the surface of the controller with a soft moist cloth Do not use abrasive detergents petrol alcohol or solvents Notice The information in this document is subject to change in order to improve reliability design or function without prior no...

Страница 4: ...ssion further manufacture other use or resale of the products whether used alone or in combination with any other products or materials ASCPL makes NO other warranty expressed or implied and makes no warranty of merchantibility or fitness for any particular purpose From time to time buyers might call to ask ASCPL for technical advice based upon limited facts disclosed to ASCPL If ASCPL furnishes t...

Отзывы: