E1 Parameter

Function : Relay status on
Probe Failure.

press the 
SET key.

To change  
the E1 
parameter

Use UP/DOWN keys to set desired 
value.

0 = Relay status is ON. 
1 = Relay performs a duty cycle

      OFF. 
2 = Relay status is OFF.

When set to 

      10 minutes ON and 4minutes 

0

2

1

Min

Max

Fac.

RS = 0 / 1

PO Parameter

Function : To enable/disable Power 
Switch.

To change 
the PO 
parameter 
press the 
SET key.

0

1

0

Min

Max

Fac.

RS = 0 / 1

If press for 2 seconds controller will 
go  in  stand  by  mode,  display  will 
show  “OF”.  To  again  switch  to 
ACTIVE  WORKING  MODE,  press 
power   switch again for 2 seconds. 
All  leds  and  7-segment  display  will 
flash  and  enter  into  NORMAL 
WORKING MODE.

Use UP/DOWN keys to get desired 
value  &  press  SET  key  to  confirm.

0 = Disable power switch

Controller  has  power  switch,  which
if enable puts controller in active or
stand by state.

1 = Enables power switch

RS Parameter

Function : To change the resolution.

To change 
the FS 
parameter 
press the 
SET key.

0

1

0

Min

Max

Fac.

RS = 0 / 1

Use UP/DOWN keys to set desired 
value. 

Note  :  Temperature  and  parameter 
will also change accordingly.

If this parameter when set to 1,it will 

0

take all parameter in 1 C resolution.

If this parameter when set to 0,it will 

0

take  all  parameter  in  0.1 C 
resolution.

LP Parameter.

Function: To lock keypad.

To change 
the LP 
parameter
press the 
SET key.

1 = keypad locked 

This parameter can lock the keypad 
so that tampering is not possible by 
by-standers.

0 = keypad unlocked

When  locked  all  parameters  can 
only be viewed, but not modified.

Use UP/DOWN keys to set desired 
value.

0

1

0

Min

Max

Fac.

RS = 0 / 1

FS Parameter

Function : To restore default
settings of the controller.

To change 
the FS 
parameter 
press the 
SET key.

0

1

0

Min

Max

Fac.

RS = 0 / 1

When  set  to  1  all  parameters  are 
programmed  to  factory  values.
Useful  to  debug  setting  related 
problems.

16

EP Parameter

To end
programming 
press the 
SET key

Once  the  SET  key  is  pressed,  the 
control  goes  into  the  normal  mode 
and displays the temperature and all 
settings are recorded.

Function: To end programming.