The  SZ-7511-WV  controller  can  be  used  for  several 

O

O

applications with a measuring range from -40 C to 99 C (1

O

O

O

Resolution

) or  -40.0 C to 50.0 C (0.1 C Resolution)

A number of parameters are displayed alphanumerically to set 
up the instrument for each specific application.

Additionally these controllers offer several protection features 
that are easily understood by the examples in the instructions 
below.  The  controller  can  be  used  for  heating  applications, 
when the P1 parameter is set to “1”.

The SZ-7511-WV are aesthetically superior versions of their 
predecessors. The SZ-7511-WV is a single set point controller 
It is specifically designed for refrigeration applications wherein 
the  compressor  cuts  off  at  set  point  and  is  restarted  at  a 
temperature of set point plus differential.

Instructions

 

:

3

INDEX

Para. Page

Description

2

To set other
Parameters.

Display will show P1 & flash.
To go to other parameters,
use UP/DOWN  keys.

Press & hold
the DOWN(prg)
key for 
2 seconds. 

prg

To set the SET Point of the controller.
How to set other parameters.
To set Heating or Cooling function.
Max High Temp limit.
Min Low Temp limit.
To set Differential (Hysterisis).
Probe calibration.
Time Delay (relay restart after cutoff)
Keypad lock.
Relay status on probe failure.
To enable/disable power switch.
To change the resolution.
Restore factory defaults.
End Programming.
Operating messages.
Technical Data.
Suggested Wiring diagram.

3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19

P1
P2
P3
P4
P5
P6
LP
E1

PO
RS

FS
EP

Function: To set the cut out point 
of the controller.

Display will change to set value. 
The set point value can now be 
changed by using the UP/DOWN 
key. After setting the desired 
value, press the set key and you 
will see “- - -” which confirms that 
the set point has been stored in 
memory.

Set point