Sub-Zero SZ-7505T Скачать руководство пользователя страница 2

LL 

Last low temperature  

Last low temperature 
logged.

LH 

Last high temperature  

Last high temperature 
logged.

Probe fail 

PP 

Probe short circuit, circuit 
open or without probe, or 

0

temperature is > 99 C or 

0

<-45 C 

OPERATING MESSAGES

EP Parameter

6

Function: To end programming.

Once the  key is pressed, the indicator goes 
into  the  normal  mode  and  displays  the 
temperature and all settings are recorded.

T
programming 
press "

SET

" key

o end 

FS Parameter

5

Function : To restore default settings of the 
indicator.

When set to 1 all parameters are programmed to factory set 
values.
Useful to debug setting related Problems.

When set to,
0 = FS is disable.
1 = FS as per default value.

Min

Max

Fac.

0

1

0

Password function

   In Program mode:

Touch & hold "      " key for 2sec. Display will flash "P5" 

parameter if "PA" value is kept "0". If other than "0", then "PA' 

and "0" will flash. Use "     "and  "     " keys to enter the 

password. On entering correct value, display will flash the first 

parameter 

 User can scroll through parameters using 

"     " or "      " keys. 

"P5".

High and Low temperature logging function

How to reset the Logged values

While the display is showing the logged values, if user 

touches & holds the "

SET

" key for 1sec, the logged values will 

be cleared and "

rS

" will be displayed.

Log Values will get reset after Power ON/OFF.

   

How to see the logged values:

LL  : Last Low temperature

LH : Last High temperature

Touch and hold "    " key for 1sec. display will flash “LL” and 
the corresponding temperature for 4 seconds.  After this, 
display will flash “LH” and the corresponding temperature for 
4 seconds and come out of Log mode and will display 
Control probe temperature.

Disclaimer:

 This manual & its contents remain the sole property of  

PVR    CONTROLS  .  India  and  shall  not  be  reproduced  or 
distributed  without  authorization. Although  great  care  has  been 
taken  in  the  preparation  of  this  document,  the  company  or  its 
vendors  in  no  event  will  be  liable  for  direct,  indirect,  special, 
incidental  or  consequential  damage  arising  out  of  the  use  or 
inability to use the product or documentation, even if advised of the 
possibility  of  such  damages.  No  part  of  this  manual  may  be 
reproduced or transmitted in any form or by any means without the 
prior  written  permission  of  the  company.  PVR  CONTROLS., 
reserves the right to make and changes or improvements without 
prior notice.

Warranty:

 This product is warranted against defects in materials 

and  workmanship  for  a  period  of  one  year  from  the  date  of 
purchase. During the warranty period, product determined by us to 
be defective in form or function will be repaired or, at our option, 
replaced at no charge. This warranty does not apply if the product 
has been damaged by accident, abuse, and misuse or as a result of 
service or modification other than by the company. This warranty is 
in lieu of any other warranty expressed or implied. In no event shall 
the  company  be  held  liable  for  incidental  or  consequential 
damages,  including  lost  revenue  or  lost  business  opportunity 
arising from the purchase of this product.

Ball Valves

Globe Valves 

Hand Valves

Flow Switches

Solenoid Valves

R

Cold Room Controller

Chiller Controller

Two Compressor Controller

Heating Controller

Humidity Controller

Pressure Controller

TM

OUR OTHER PRODUCTS

00 / 19.05.17

7

LP Parameter

4

Min

Max

Fac.

0

1

0

Function: To lock keypad.

Flashing

When  locked  all  parameters  can  only  be  viewed,  but  not 
modified.

Note :

 If LP parameter is set to 1 and if user tries to change any 

parameter value, " LP" will flash on the display.

This parameter is used to lock the keypad so that tampering is 
not possible by by-standers.

0 = keypad unlocked
1 = keypad locked 